Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs — 现代 SSD 中读干扰对系统级性能影响的实验研究
现代 SSD 中读干扰对系统级性能影响的实验研究 本文附英文原文(arXiv 全文/PDF 提取)与中文深度解读。
原文:Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs,作者 Yonggon Park, Hyunuk Cho, Onur Mutlu, et al. (POSTECH & ETH Zurich)。 本页结构:第一部分为英文原文(Original Article),第二部分为中文深度解读(解析)。 说明:原文无付费墙,全文完整收录(来自 arXiv HTML 或 PDF 文本提取,公式以 LaTeX 呈现)。
第一部分:正文(Original Article)
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs YONGGON PARK,POSTECH, Republic of Korea HYUNUK CHO,POSTECH, Republic of Korea ONUR MUTLU,ETH Zurich, Switzerland SUNGJIN LEE,POSTECH, Republic of Korea JISUNG PARK,POSTECH, Republic of Korea This work investigates the system-level performance impact of read disturbance in modern NAND flash-based SSDs, aiming to provide new insights that can help develop better storage architectures and optimize system software. Continuous improvement in storage density over decades has led NAND flash memory to play a vital role in modern computing systems, but it also comes at a cost of significant reliability degradation. Among various error sources, read disturbance has gained growing attention as a major reliability concern due to its rapidly increasing impact, which can significantly affect system I/O performance by exacerbating SSD-internal reliability-management overheads. Although a large body of prior work has focused on device- level characterizations and optimizations, the system-level performance impact of read disturbance still remains largely uninvestigated. To address this gap, this work conducts a rigorous experimental study using 15 modern NVMe SSDs from 10 major vendors in two ways. First, we comprehensively analyze the system-level performance impact of read disturbance under diverse workloads and operating conditions. Second, to highlight the importance of efficient read-disturbance management, we showcase a new possible SSD-performance attack as a case study, demonstrating that an adversary can significantly degrade the I/O performance of other concurrently running processes by exploiting read disturbance alone in commodity SSDs. Based on our experimental study, we make 16 new observations and 7 takeaway lessons, which lead to 6 key directions for future improvements at the host-system and SSD-architecture levels to better cope with read disturbance. CCS Concepts:•Information systems→Flash memory;•Hardware→External storage. Additional Key Words and Phrases: solid state drives (SSDs), NAND flash memory, read disturbance, I/O performance, performance analysis ACM Reference Format: Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park. 2026. Experimental Study on System- Level Performance Impact of Read Disturbance in Modern SSDs.Proc. ACM Meas. Anal. Comput. Syst.10, 1, Article 10 (March 2026), 32 pages. https://doi.org/10.1145/3788092 1 Introduction Owing to the continuous and significant improvements in storage density over decades, NAND flash memory has become the predominant memory technology for modern storage systems. Since 2014, the storage density of NAND flash memory has almost doubled every two years [1, 2], which has enabled modern solid-state drives (SSDs) to offer unprecedented single-device capacities (e.g., 128 TB [3]) at a lower cost per bit. Three key technologies have driven such advancement: (i) aggressive process scaling, which packs more cells into the same die area, (ii) multi-level cell (MLC) techniques, which allow each cell to store multiple bits (e.g., triple-level cell (TLC)), and (iii) 3D stacking, which vertically integrates hundreds of wordline (WL) layers in a NAND flash die. Unfortunately, the continuous storage-density improvements come at a cost of significant reliabil- ity degradation in modern NAND flash memory, aggravating the reliability impact of various error sources, such as read disturbance [4–11], program interference [12–15], and retention loss [16–19]. NAND flash memory stores data based on a cell’s threshold voltage (VTH) level that highly depends on the amount of charge inside the cell. The unique cell designs and organizations of 3D NAND arXiv:2608.14073v1 [cs.AR] 14 Aug 2026
10:2 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park flash memory render flash cells more susceptible to charge leakage [16, 19] and circuit-level distur- bance [6–8]. Storing more bits in a smaller cell reduces the margin between different VTH levels, drastically increasing the reliability impact of VTH shifts caused by the error sources [20]. Among the various error sources,read disturbancehas gained increasing attention as a major reliability concern in modern NAND flash memory. To read a page from a target WL, NAND flash memory needs to apply high pass-through voltage VPASS (e.g., 6 V) toallnon-target WLs in the same block, which unintentionally programs the WLs slightly. Such disturbance can cause data corruption (i.e., a permanent data loss) when a block experiences a large number of page reads, e.g., 400K [6]. The disturbance effect of a single page read significantly increases in modern NAND flash memory due to two key reasons. First, reading a page from a WL requires more sensing operations in advanced MLC techniques, exposing non-target cells to high VPASS for a longer time. Second, a single page read disturbs more pages, as the number of pages per block increases rapidly. The increasing reliability impact of read disturbance, in turn, can significantly affect the perfor- mance of modern SSDs, exacerbating the overheads of SSD-internal tasks, such asread retry[21, 22] andread reclaim[ 4, 5, 23]. When the SSD controller fails to correct all the raw bit errors in a read page with error-correcting codes (ECC), itretriesreading the page with adjusted read-reference voltage (VREF) levels until the page’s raw bit-error rate (RBER) decreases below the ECC’s error- correction capability. Before read retry becomes unable to sufficiently reduce a page’s RBER due to excessive read disturbance, the SSD controller needs to perform read reclaim that removes the page’s transient errors by rewriting its data to another free page. Even though both read retry and read reclaim are essential to ensuring the reliability of stored data, their additional read and write operations can significantly affect SSD performance [6, 21, 24]. To cope with the increasing reliability impact of read disturbance, modern SSDs need to invoke read retry and read reclaim more frequently, aggravating their performance overheads. Our goalin this work is to provide new insights into the system-level performance impact of read disturbance in modern NAND flash-based SSDs, which has not yet been thoroughly investigated in the literature, but can help develop better storage architectures and optimize system software. To this end, we conduct a rigorous experimental study using 15 modern NVMe SSDs [25–39] from 10 major vendors in two ways. First, we analyze the system-level performance impact of read disturbance under diverse workloads and operating conditions to (i) evaluate the effectiveness of existing reliability-management techniques in modern SSDs, (ii) identify their limitations, and (iii) explore new optimization opportunities. Second, as a case study, we showcase a new possible SSD-performance attack that can severely degrade the I/O performance of other applications sharing the same SSD by causing excessive overheads for read-disturbance management, highlighting the importance of efficient read-disturbance management in modern storage systems. Based on our experimental study, we make 16 key observations and 7 takeaway lessons, which lead to 6 key directions for future improvements at the host-system and SSD-architecture levels to better cope with read disturbance. We highlight four observations that are especially important. First, read disturbance can significantly degrade SSD performance, e.g., lowering read bandwidth by more than 79.1% for 32.7 seconds, even under sequential-read workloads that are commonly considered best for SSD performance in prior work [ 40–42]. Second, severe and consistent performance fluctuations can occur for a long time (e.g., several hours) in modern SSDs when a number of blocks trigger read-disturbance management tasks simultaneously. Third, the performance impact of read disturbance highly depends on SSD-internal management, significantly varying even across SSDs using the same NAND flash chips. Fourth, an application’s I/O performance can significantly degrade due to read disturbance caused by other applications sharing the same SSD. Our case study experimentally demonstrates a new possible performance attack that can cause significant I/O slowdowns to other concurrent processes by exploiting read disturbance. The attack
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:3 issues only sequential reads within its own exclusive logical-block address (LBA) rangewithout requiring direct access to the target application’s data, any host-privilege escalation, or more CPU cores than the target. Our evaluation shows that the attack can (i) burst significant performance fluctuations within a short time window and/or (ii) sustain long I/O slowdowns, which severely affect both the I/O bandwidth and read tail latency of other applications that share the same SSD. This work makes the following key contributions: • We present the first rigorous study on the system-level performance impact of read disturbance by testing 15 commodity NVMe SSDs under various operating scenarios, which leads to 16 new observations that highlight the importance of efficient read-disturbance management. • We propose a new possible SSD-performance attack that can severely degrade a target applica- tion’s I/O performance by exacerbating read-disturbance management overheads, experimentally demonstrating the attack’s feasibility and effectiveness in commodity SSDs. • Based on our new observations, we present six future improvements to better cope with read disturbance that becomes more severe as the storage density of NAND flash memory increases. 2 Background We provide a brief background on modern SSDs necessary to understand the rest of the paper. 2.1 NAND Flash-Based SSDs Fig. 1(a) shows an organizational overview of modern NAND flash-based SSDs that commonly consist of three key components: (i) NAND flash array, (ii) SSD controller, and (iii) internal DRAM. NAND Flash Array.Fig. 1(b) illustrates the hierarchical organization of 3D NAND flash memory. A group of vertically stacked flash cells are serially connected, which is called aNAND string. Each NAND string is connected to a bitline (BL), and NAND strings in the same 𝑦-𝑧 plane constitute asub-block, where a single wordline (WL) connects all flash cells at the same vertical location. A blockcomprises multiple sub-blocks (e.g., 2 to 8) of which WLs at the same vertical location are connected and thus share the same WL voltage. Aplaneconsists of hundreds of blocks that share all BLs in the plane. Adie(or achip) contains several planes (e.g., 4 or 6), and multiple dies can be packaged together while sharing the package’s command and data bus, i.e., achannel. Modern SSDs contain a large number of dies that can concurrently operate (e.g., 32 dies [43]), enabling high internal parallelism. To enhance random-read performance, manufacturers have recently developed the independent-plane read [44] that allows multiple planes in the same die to perform page reads independently of each other. Despite the high die- and plane-level parallelisms, SSD performance is often bottlenecked by the channel transfer rate (e.g., 1.2–2.4 GB/s [43, 45, 46]) due to the limited number of channels (e.g., 8 or 16 [47]) that connect the dies to the SSD controller. Sub-blockSub-blockSub-blockSub-block(b) NAND flash array WL1 WL2 WLm………………… BL1BL2BLn…xyz (a) NAND flash-based SSD SSDControllerEmbed.CoreEmbed.CoreEmbed.CoreInt. DRAML2PMappingsFlash Translation LayerFlashControllerReq. HandlerECC …FlashCtrl. 1FlashCtrl. 2FlashCtrl. NChannelNAND DieNAND DieNAND Die NAND String Die 1… Peripheral Internal ChannelDie 2Die NPlane 1Plane 4Block 1Block 2Block 1Block 2……… Fig. 1. Overview of modern NAND flash-based SSD.
10:4 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park SSD Controller.An SSD controller consists of (i) multiple embedded cores and (ii) hardware flash controllers. The cores run SSD firmware, calledflash translation layer(FTL), which performs various internal management tasks, such as address translation [48–50], garbage collection [51–59], reliability management [6, 12, 14, 18, 19, 23], wear leveling [60–62], request scheduling [63–67], etc. A flash controller is in charge of request handling, data randomization, and error-correcting codes (ECC) for the associated NAND flash dies. Modern SSDs typically employ 8 to 16per-channel flash controllers to prevent ECC from delaying data transfer through the channels [68–70]. Internal DRAM.Modern SSDs employ large low-power DRAM (e.g., several GBs [71]) for metadata store and data buffer. Except for some cost-optimized SSDs [33, 34, 72], it is common to keep all logical-to-physical (L2P) address mappings in internal DRAM to avoid expensive NAND flash accesses for address translation. Doing so requires 0.1% of the SSD capacity to support 4-KiB mapping granularity [48, 73], which consumes most of the internal DRAM capacity. FTL also needs to maintain various metadata for reliability management, such as the program and erase (P/E)-cycle count, retention age, and read count for each block. A small fraction of internal DRAM (e.g., tens of MBs [74]) is used as a write buffer to hide the long write latency of NAND flash memory [75, 76]. 2.2 NAND Flash Operations Three basic operations enable access to NAND flash memory: (i) program, (ii) erase, and (iii) read. Program and Erase Operations.A flash cell stores data using its threshold voltage (V TH) level that can change in a nonvolatile manner depending on the amount of charge in the cell’s floating gate or charge trap. A program operation injects electrons into target cells at a page granularity (e.g., 16 KiB), increasing their VTH levels. An erase operation ejects electrons from target cells at a block granularity, which decreases their VTH levels. Injecting/ejecting electrons into/from a large number of cells requires applying a high voltage (e.g.,>20 V) to the cells for a long time (e.g., 400µs and 3.5 ms for program and erase operations, respectively), which physically damages target cells. Read Operation.NAND flash memory reads stored data from target cells at a page granularity by identifying whether current flows through the corresponding NAND strings [21, 77, 78]. When applying read-reference voltage VREF to a target WL, the cells connected to the WL operate as either a resistor (if VTH<VREF) or an open switch (if VTH>VREF). A NAND flash chip also applies pass voltage VPASS to other WLs in the same block which is high enough (e.g., 6 V) to make all non-target cells operate as a resistor regardless of their VTH levels. Doing so ensures that only a target cell’s VTH level dictates the corresponding NAND string’s conductance. If the NAND string conducts flow, the sensing logic interprets the cell’s data as ‘1’; otherwise, it reads as ‘0’. 2.3 Reliability Issues in Modern SSDs NAND Flash Reliability.NAND flash memory is error-prone due to a variety of error sources, such as read disturbance [4, 5, 8–10], program interference [12–15], and retention loss [16–19]. Fig. 2 shows the VTH distribution of a WL, when programmed in (a) single-level cell (SLC) and (b) triple-level cell (TLC) modes to store one and three bits per cell, respectively. Read and program operations unintentionally program other non-target WLs in the same block, slightly increasing the cells’ VTH level (i.e., disturbance and interference). A flash cell leaks its charge over time, which decreases its VTH level (i.e., retention loss). If a cell’s V TH level shifts beyond VREF, sensing the cell leads to a different value from the programmed originally, causing a bit error. Two major factors significantly degrade the reliability of NAND flash memory. First, the multi-level cell (MLC) technique drastically reduces the VTH margins to pack more VTH states within the limited voltage window. Second, the high voltage applied to target cells during program and erase operations physically damage the cells, making it easier for the cells to gain or lose electrons more easily.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:5 Programmed VTHDesign Limit
of cells VTH
VREFRetention lossDisturbance/Interference0VTH MarginErased (E)1
of cellsVTH Margin
(a) SLC NAND flash memory (b) TLC NAND flash memory VREF0 111E VREF1 110P1 101P7 VREF2 100P2 VREF3 000P3 VREF4 010P4 VREF5 011P5 VREF6 001P6 Errors MSBCSBLSB Fig. 2. V TH distributions of NAND flash memory cells. Reliability Management.There are four reliability-management techniques widely adopted to guarantee the integrity of stored data: (i) ECC, (ii) read retry, (iii) data refresh, and (iv) patrol read. First, ECC detects and corrects raw bit errors in a read page [79–81]. After reading the data from the flash memory, the flash controller detects and corrects the errors using the ECC parity that is stored in the out-of-bound (OOB) area of the same WL [ 79–83]. Second, if a read page’s raw bit-error rate (RBER) exceeds the ECC capability, the SSD controller performs read retry that reads the page again with adjusted VREF levels until sufficiently lowering the page’s RBER [21, 22]. Third, to avoid potential data corruptions due to excessive RBER that even read retry cannot handle, the SSD controller proactively refreshes stored data. For example, if a block’s read count (i.e., the number of page reads to the block) exceeds a threshold (e.g., 400K [ 6]), the SSD controller can eliminate transient errors stemming from read disturbance by copying the block’s valid data to free pages, which is calledread reclaim. Fourth, to proactively mitigate the overheads of ECC-decoding and read retry, some SSDs employpatrol reads, which periodically read stored pages to (i) check their RBER and (ii) identify the near-optimal VREF levels for future reads [84–86]. These reliability-management techniques enable modern SSDs to meet the strict unrecoverable bit-error ratio (UBER) requirements of <10−15 [87], despite the continuously degrading NAND flash reliability. In practice, SSD controllers escalate to stronger and more expensive techniques as RBER increases. For example, an SSD controller first performs hard-decision ECC decoding, which provides the lowest latency but also the weakest error-correction capability. If hard-decision ECC decoding fails, the controller invokes more expensive recovery steps, such as read retry and soft-decision ECC decoding, and ultimately performs the data-refresh operations (e.g., read reclaim) when necessary. This progressive recovery process allows SSDs to successfully service nearly all I/O requests even under worst-case operating conditions (e.g., 1-year retention at 1.5K PEC [88, 89]) at the cost of degraded I/O performance. When an error remains uncorrectable even after the whole recovery process, the SSD reports it to the host as aread failurerather than returning corrupted data, i.e., a successful read completion implies that no data corruption has been detected. 3 Motivation Read disturbance has gained growing attention recently due to its increasing reliability impact. Reading a page causes higher disturbance in modern NAND flash memory for two key reasons. First, the advanced multi-level cell (MLC) techniques require more sensing steps for a page read, e.g., up to four sensing steps in quad-level cell (QLC) NAND flash memory, which significantly increases the read latency and thus exposes non-target cells to high VPASS for a longer time. Second, a single
10:6 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park read operation disturbs more non-target pages, as the block size in modern NAND flash memory rapidly increases (e.g., recent QLC NAND flash memory contains 2,816 pages per block [90]). The increasing reliability impact of read disturbance, in turn, can significantly degrade the I/O performance of modern SSDs, aggravating reliability-management overheads. As the RBER of a larger number of pages increases more rapidly, the SSD controller needs to perform read retry and read reclaim more frequently, which introduces significant performance overhead due to additional read and copy operations, respectively. Although prior studies have proposed various techniques to mitigate read retry overhead [21, 22], read reclaim’s copy overhead rather severely increases in modern NAND flash memory due to the increased block size, i.e., read reclaim needs to copy a large number of pages in the target block. Such increased overheads can affect application performance more seriously in modern computing systems, where a variety of data-intensive applications consistently read massive amounts of data from high-performance SSDs. Nevertheless, no prior work has yet thoroughly investigated the system-level performance impact of read disturbance in practice. To our knowledge, only one recent study [5] has demonstrated that read reclaim can degrade the I/O response time and lifetime of commodity SSDs, which motivates adaptively delaying read reclaim and relying more on other reliability-management techniques to mitigate performance degradation. In the prior study, however, most evaluated SSDs are outdated in terms of storage interface (SATA) and NAND flash technology (2D or early 3D NAND flash memory) [91–100], and only one workload (16-KiB random reads) is used. With such outdated SSDs and limited workload, it is difficult to provide sufficient insights for a comprehensive understanding of the performance impact of read disturbance in modern SSDs that serve diverse I/O patterns with high-bandwidth interface (e.g., NVMe) and high-density (yet low-reliability) NAND flash memory. Our goalis to provide new insights into the system-level performance impact of read disturbance in modern NAND flash-based storage systems, which can help develop better storage architecture and optimize system software (e.g., operating-systems I/O stack and SSD firmware) to better cope with ever-increasing I/O-performance demands from data-intensive applications. To this end, we conduct a comprehensive experimental study that characterizes the performance of modern NVMe SSDs under different access patterns and operating conditions. 4 Characterization Methodology This section presents our methodology for characterizing the impact of read disturbance on the system-level performance in modern NAND flash-based SSDs. 4.1 Testing Infrastructure Tested SSDs.Table 1 summarizes the key characteristics of the 15 commodity SSDs from 10 vendors that we test [25–39]. We characterize recent M.2 NVMe SSDs that employ advanced 3D TLC/QLC NAND flash memory with 96–232 stacked-WL layers. To analyze the impact of SSD firmware, we test several SSDs that use the same NAND flash chips, i.e., chips from the same NAND manufacturer with the same number of WL layers and the same MLC technology. All tested SSDs support PCIe Gen 4 interface (four lanes), offering high sequential-read bandwidth. For rapid characterization, we select SSD models that provide 500-GB or 512-GB storage capacity. Even though process variation across NAND flash chips [9, 101–109] may lead to different performance behaviors even across SSDs of the same model, such within-model differences are not the focus of this work. We expect any remaining differences to have limited impact on the system-level behaviors investigated in this study, given that SSD manufacturers generally aim to deliver consistent performance across devices of the same model (e.g., by using NAND flash chips with similar characteristics or wafer locations). We leave a systematic investigation of within-model performance variation for future work.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:7 Table 1. Specifications of 15 commodity SSDs tested. SSD ID Read Performance Hardware Specification Release YearSeq. [MB/s] Rand. [IOPS] NAND Mfr. WL Layers/MLC Capacity Int. DRAM SSD-A6,400 800K Mfr. A 128/TLC 500 GB 512 MB 2020 SSD-B7,000 800K Mfr. B 96/TLC 500 GB 512 MB 2020 SSD-C4,125 390K Mfr. C 144/QLC 512 GB DRAM-less 2022 SSD-D6,900 800K Mfr. A 128/TLC 512 GB 512 MB 2020 SSD-E7,300 450K Mfr. D 176/TLC 500 GB 512 MB 2021 SSD-F4,700 N/A Mfr. D 232/TLC 500 GB DRAM-less 2022 SSD-G7,000 960K Mfr. E 176/TLC 500 GB 512 MB 2022 SSD-H7,000 750K Mfr. F 112/TLC 512 GB 512 MB 2022 SSD-I4,200 400K Mfr. D 176/QLC 512 GB DRAM-less 2022 SSD-J7,200 800K Mfr. D 232/TLC 500 GB 512 MB 2023 SSD-K7,000 400K Mfr. D 176/TLC 500 GB 512 MB 2021 SSD-L7,000 540K Mfr. D 176/TLC 512 GB 512 MB 2022 SSD-M7,000 960K Mfr. E 176/TLC 512 GB 512 MB 2022 SSD-N6,300 567K Mfr. G 232/QLC 512 GB DRAM-less 2023 SSD-O6,600 360K Mfr. D 176/TLC 512 GB 1 GB 2021 SSD Testing Setup.We set up our test environment using eight Linux machines, each containing an Intel i9-14900K CPU [110], four 16-GB DDR4-3200 MHz DRAM modules, and a 4-TB Samsung 990 Pro SSD [71]. We run FIO benchmark tool [111] to issue I/O requests to the tested SSDs while collecting log data for every 100 ms using the main storage device.1 While running FIO, we (i) enable a direct I/O option to bypass the host memory buffer when accessing tested SSDs and (ii) use the libaio I/O engine to saturate SSD performance. To avoid potential interference, we evaluate only one SSD at a time on each machine. We check S.M.A.R.T. logs [112–114] to obtain internal information of tested SSDs, such as their remaining lifetime and operating temperature. Each SSD is installed with a heat sink to minimize thermal throttling, allowing the SSD to operate at a stable temperature range of 40–75◦C, belowWarning Temperature Threshold(85 ◦C) specified by the S.M.A.R.T. attribute. We do not observe any temperature-induced throttling when using a heat sink, which can otherwise occur when running experiments without one. 4.2 Testing Methodology SSD Preconditioning.We precondition all SSDs for each read-disturbance test in three steps to avoid potential distortions caused by any factor other than read disturbance. First, we issue TRIM commands to the entire logical block address (LBA) range to minimize possible variations in data layout and garbage collection. Second, we fill up 90% of SSD logical capacity, a host-visible LBA space which excludes over-provisioned area and metadata, by sequentially writing 450 GB of data starting from LBA 0. Doing so ensures that the read data has been programmed in TLC/QLC blocks rather than in the SLC buffer [ 115, 116]. Third, we give a 30-minute idle time before each test, which provides sufficient time for SSDs to perform internal tasks such as garbage collection and SLC-buffer flush as they need. Read-Disturbance Test.We analyze the performance impact of read disturbance in the 15 SSDs while varying access patterns and SSD-lifetime stages. We accumulate read disturbance to SSDs under sequential- and random-read workloads generated from FIO with the configurations widely used for SSD-performance specification [117]: (i) queue depths (QD) of 32 and 128, (ii) I/O sizes of 1 MiB and 4 KiB, and (iii) thread counts of 1 and 16, respectively. We expect this configuration to 1We set the logging interval to 100 ms to reduce the log file size, which we verify is sufficient to capture all performance patterns observed at shorter intervals (e.g., 5 ms).
10:8 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park be sufficient to fully saturate the NAND flash chips, thus minimizing performance impacts from plane-level load imbalance. We perform tests while varying the consecutive LBA range to be read, referred to asread range, from 64 MB to 50 GB; we read the middle of the 450-GB preconditioned data (e.g., 50-GB reads starting at a 200-GB offset) to avoid reading data in the SLC buffer. This is because we observe that some tested SSDs retain either the oldest or the newest data in the SLC buffer even after long idle times. Reading such data yields artificially high performance, which hinders characterizations of common and worst-case scenarios. All read requests complete successfully without errors in all tests, i.e., no data corruption occurs, as explained in §2.3. We evaluate SSDs under three lifetime stages, early, middle, and late, each corresponding to 0%, 50%, and 80% of their lifetime usage, respectively. This is motivated by prior findings that read disturbance becomes more severe with higher program/erase (P/E) cycles [8, 118]. Touniformly increase P/E-cycle counts (PEC), we repeat sequential writes to the entire LBA range of the SSDs. We observe that some SSDs occasionally produce variations in test results. We hypothesize that these are caused by different data layouts across tests, which is challenging to control. For such SSDs, we repeat the tests five times or more and use the most dominant result. 5 Characterization Results We present our characterization results on the system-level performance impact of read disturbance in modern SSDs, introducing eleven new observations and five key takeaways. 5.1 Impact of Access Patterns We first analyze how read disturbance affects SSD performance under sequential and random reads. Sequential-Read Pattern.Fig. 3 shows the performance of the 15 SSDs during the sequential-read test for 30,000 seconds with a read range of 1 GB at early lifetime stages. Each data point indicates the amount of data read during one second. We also plot (i) the sequential-read performance specified by the manufacturer and (ii) the average bandwidth actually measured during the test. We make three key observations from Fig. 3. Observation 1.A majority of the tested SSDs fail to match their performance specifications. All SSDs except for SSD-F and SSD-G exhibit significantly lower performance compared to the specification by 36.74% on average (up to 95.5% in SSD-N). SSD-E/-I/-L/-N fail to achieve half the specified performance even at the beginning of the tests. The results suggest that (i) the specified performance could be measured in the best-case scenario, e.g., when reading data stored in the SLC buffer [115, 116], and (ii) an SSD may not meet its performance specification in practice even under a sequential-read workload (which is considered best for SSD performance [42, 119–121]). Observation 2.Most tested SSDs exhibit significant performance fluctuations consistently. Table 2 summarizes each SSD’s performance-drop patterns, where the drop duration and period represent the time required for an SSD to recover near-peak bandwidth and the time until the next performance drop, respectively, since a drop occurs. All tested SSDs except for SSD-F and SSD-H exhibit a significant gap between the peak and minimum bandwidth values. In particular, SSD-A’s read bandwidth periodically drops to ~1 MB/s, which means that it can hardly service user reads for one second, significantly increasing the read tail latency. The 1st-percentile (P1) bandwidth is close to the minimum bandwidth (<20% differences) in half of the SSDs (SSD-C/-E/-G/-I/-J/-K/-M/ -N), and the 10th-percentile (P10) bandwidth is lower than the peak bandwidth by more than 30% in SSD-C/-L/-N/-O. The results highlight the consistent performance impact of read disturbance in modern SSDs. Such performance fluctuations, in turn, considerably degrade the average bandwidth in most tested SSDs compared to their peak bandwidth by 22.1% on average (up to 83.8% in SSD-N).
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:9 8 04(a) SSD-A (b) SSD-B (c) SSD-C Bandwidth [GB/s] Average BWPerformance specificationRead BW (per second) (g) SSD-G (h) SSD-H (i) SSD-I8 04 (j) SSD-J (k) SSD-K (l) SSD-L8 04 Time [103 seconds]302010 302010 302010 (m) SSD-M (n) SSD-N (o) SSD-O8 04 8 04(d) SSD-D (e) SSD-E (f) SSD-F Fig. 3. Sequential-read test results with 1 GB read range. Table 2. Performance-drop patterns during the sequential read test with a read range of 1 GB. SSD ID Read Bandwidth (Normalized to Peak) [MB/s] Drop Timing [seconds] Peak Avg. Min. P1. P10. Duration Avg. Period SSD-A6,026 5,768 (95.7%) 1 (<0.1%) 4,344 (72.1%) 5,145 (85.4%) 775–1.7K 3.9K SSD-B5,423 5,313 (98%) 1,231 (22.7%) 4,396 (81.1%) 5,153 (95%) 2.2K>10K SSD-C3,144 2,650 (84.3%) 1,504 (47.8%) 1,586 (50.4%) 1,929 (61.4%) 2.3K–3.5K 2.7K SSD-D5,695 5,646 (99.1%) 1,099 (19.3%) 5,621 (98.7%) 5,636 (99%) 2–4 2.7K SSD-E2,118 1,914 (90.4%) 346 (16.3%) 432 (20.4%) 1,883 (88.9%) 1–2 156 SSD-F4,371 4,307 (98.5%) 4,102 (93.8%) 4,286 (98.1%) 4,294 (98.2%) N/A 1 N/A1 SSD-G6,818 6,767 (99.3%) 4,674 (68.6%) 5,073 (74.4%) 6,794 (99.6%) 5–7 331 SSD-H5,761 5,649 (98.1%) 5,546 (96.3%) 5,597 (97.2%) 5,622 (97.6%) N/A 1 N/A1 SSD-I1,786 1,749 (97.9%) 1,172 (65.6%) 1,389 (77.8%) 1,739 (97.4%) 15–65 1.0K SSD-J6,692 6,427 (96%) 3,011 (45%) 3,200 (47.8%) 6,643 (99.3%) 1–5 13 SSD-K6,531 5,611 (85.9%) 4,529 (69.3%) 4,988 (76.4%) 5,293 (81%) 12–21 672 SSD-L6,638 3,039 (45.8%) 1,456 (21.9%) 2,143 (32.3%) 2,197 (33.1%) 3–4 1.1K SSD-M6,813 5,388 (79.1%) 3,573 (52.4%) 4,479 (65.7%) 5,207 (76.4%) 5–7 420 SSD-N1,741 282 (16.2%) 58 (3.3%) 59 (3.4%) 59 (3.4%) 1–243 37 SSD-O6,363 4,299 (67.6%) 1,084 (17%) 2,776 (43.6%) 2,821 (44.3%) N/A 2 N/A2 N/A: 1no significant drops or 2too-short drop duration and period. Values in parentheses are percentages of the peak bandwidth for each SSD. We observe that SSD-F and SSD-H provide stable performance during the entire test. We hy- pothesize that those SSDs can hide the performance impact of read disturbance by efficiently leveraging their over-provisioned internal parallelism. Most tested SSDs, including SSD -F and SSD-H contain NAND flash chips more than enough to achieve their specified sequential-read
10:10 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park performance. This means that they can perform read-disturbance management tasks using such extra resources without affecting the average bandwidth. Note that, however, when we extend the test time to 1,000,000 seconds, performance drops also occur in SSD-F and SSD-H at around 45,000- and 83,000-second periods, respectively, which suggests that it is challenging to completely eliminate the performance impact of read disturbance in modern SSDs. Observation 3.There exist distinct performance-drop patterns observed across the tested SSDs. We categorize the tested SSDs into two groups based on whether they attempt to maintain near- peak performance (Type-1) or not (Type-2) using their performance-drop patterns as a proxy for SSD-internal behavior, since analyzing exact SSD-internal behavior is practically infeasible. We hypothesize that Type-1 SSDs (SSD-A to SSD-J) actively perform read-disturbance management tasks, such as read reclaim and patrol reads, which cause steep yet short performance drops but prevent long-term slowdowns. In contrast, Type-2 SSDs (SSD-K to SSD-O) appear to defer read reclaim as much as possible while relying on other reliability-management techniques, e.g., read retry [21] and strong ECC [22], to avoid significant increases in read tail latency. We validate our hypothesis based on the SSD-internal statistics that can be obtained for some SSDs 2 from the vendor-specific S.M.A.R.T. attribute. Once performance fluctuation occurs in SSD -E and SSD-J (Type-1), theirdevice lifetime percentageandinternal flash writevalues increase by up to 1% and 516 GB, respectively, even though no user write has been issued, which strongly suggests that the performance fluctuation is likely to be caused by read reclaim. In contrast, such attributes never increase in SSD-K to SSD-O (Type-2) during the entire test. Note that, however, detailed performance-drop patterns significantly vary even across SSDs using the same NAND flash chips, e.g., SSD-E/-K/-L/-O. To identify the root cause of the peak-performance degradation in Type -2 SSDs, we further analyze the performance impact of read disturbance more precisely. To this end, before and after a sequential-read test with a 1-GB read range, we profile the sequential-read bandwidth of each 32-MB region within the read range. Fig. 4 compares the read bandwidth across the 32-MB regions before and after the sequential-read test in (a) SSD -J (Type-1) and (b) SSD -M (Type-2) at early lifetime stages. Before testAfter test249.5 250.5249.5250.5 BW [GB/s] 8 04 LBA [GB] LBA [GB]250(b) SSD-M250(a) SSD-J 8 04 Fig. 4. Read bandwidth breakdown before and after test. Observation 4.Certain parts of the read range exhibit consistently degraded performance in the Type-2 SSDs, whereas the Type-1 SSDs maintain their peak performance across the entire read range after the sequential-read test. Half of the 32-MB regions in SSD-M incur 49.05% bandwidth degradation on average compared to other regions within the 1-GB read range. We observe the same trends for all Type-2 SSDs, which also supports our hypothesis that they rely on read retry or strong ECC rather than read reclaim or 2Most tested SSDs do not disclose their internal statistics.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:11 patrol reads. Prior work has demonstrated that some WLs are more susceptible to error sources than other WLs [6, 7, 101]. As the RBER of suchweakerWLs increases more rapidly compared to other WLs with the same number of page reads to the block, read disturbance can lead them to incur read retry and long ECC decoding more easily [22, 122, 123], increasing the read latency. As read disturbance accumulates, the fraction of WLs with long read latencies increases, which continuously degrades read bandwidth. Read reclaim and patrol reads can avoid such bandwidth degradation by directly reducing the RBER of read data as shown in Fig. 4(a). Takeaway 1.Read disturbance can significantly degrade SSD performance even under sequential reads, but its impact varies across SSDs (even those using the same NAND flash chips) depending on read-disturbance management. Random-Read Pattern.Fig. 5 shows the performance of the 15 SSDs during the random-read test for 30,000 seconds with a read range of 1 GB at early lifetime stages. Each data point indicates the number of read requests serviced during one second (IOPS). We also plot the random-read performance specified by the manufacturer and average IOPS measured during the entire test. We make two key observations from Fig. 5. Average IOPSPerformance specificationRead IOPS (per second)1 00.5(a) SSD-A (b) SSD-B (c) SSD-C IOPS [×106] (g) SSD-G (h) SSD-H (i) SSD-I1 00.5 (j) SSD-J (k) SSD-K (l) SSD-L1 00.5 Time [103 seconds]302010 302010 302010 (m) SSD-M (n) SSD-N (o) SSD-O1 00.5 1 00.5(d) SSD-D (e) SSD-E (f) SSD-F Fig. 5. Random-read test results with 1 GB read range. Observation 5.All tested SSDs exhibit significantly lower random-read performance than the specification, showing even larger performance gaps than in the sequential-read test. The measured IOPS is far lower than the specification by 51.93% on average across all tested SSDs,3 which is much more severe than in the sequential-read test (36.74%). The result further supports our 3We exclude SSD-F due to its lack of random-read performance specification publicly accessible. Note that SSD-F merely provides similar or lower IOPS compared to other DRAM-less QLC SSDs (SSD-C and SSD-I), which suggests that the actual performance gap could be even larger with SSD-F.
10:12 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park hypothesis in Observation 1 that most SSD manufacturers determine the performance specification in the best-case scenario. It is well known that SSDscannotdeal with small random reads as efficiently as sequential reads due to two reasons. First, the minimum I/O unit of NAND flash memory is a page (typically 16 KiB), so reading sub-page datacannotincrease throughput (IOPS), merely decreasing bandwidth. Second, the independent-plane read has been recently introduced and may not yet be adopted commonly in modern SSDs; until recently, most NAND flash chips could perform multi-plane operationsonly whentarget pages have the same block or page offsets [ 124], which is unlikely to hold under random reads, thereby significantly under-utilizing SSD-internal parallelism compared to sequential reads. Observation 6.For a majority of the tested SSDs, the performance impact of read disturbance is less significant under random reads compared to under sequential reads. We observe two key differences in the performance-drop patterns between the random- and sequential-read tests. First, no Type-2 SSDs (SSD-K to SSD-O) exhibit long-term peak-performance degradation during the random-read test, unlike during the sequential-read test. Second, a majority of the tested SSDs (SSD-A/-B/-D/-E/-F/-H/-J/-K/-L/-O) incur less significant performance fluctuation during the random-read test, showing smaller gaps between their peak and minimum performance (46.5% on average) than those in the sequential-read test (59.8%). The results align with our initial expectation; even a slight decrease in SSD-internal parallelism caused by read disturbance can significantly affect the peak performance for sequential-read workloads compared to random-read workloads (where the available parallelism is inherently limited). This highlights the importance of analyzing the performance impact of read disturbance with various workloads, suggesting that the performance impact of read disturbance demonstrated in prior work [5] (which has used only random-read workloads) might be underrated. Read disturbance-induced performance fluctuations can also be more severe in a few SSDs under random-read workloads due to two reasons. First, we hypothesize that high address-translation overhead under random-read pattern can exacerbate performance fluctuations in DRAM-less SSDs (SSD-C/-I/-N). DRAM-less SSDs store most L2P mappings in NAND flash memory [48, 72], which frequently incurs additional NAND-flash access for address translation, and, in turn, can amplify the overheads of internal reliability management that require address-mapping information. Under sequential reads, high spatial locality across accesses to L2P mappings minimizes the address- translation overhead, but it would significantly increase under random reads. Second, we assume that SSD-G and SSD-M heavily rely on locality-sensitive information for reliability management. For example, several prior works have proposed to reuse near-optimal VREF levels of recently read WLs for future reads [9, 15, 101, 125–128]. Doing so can potentially mitigate read-retry overheads for neighboring WLs of the recently read ones that would likely have similar reliability characteristics. Unfortunately, its effectiveness may degrade significantly under random reads due to the limited space for tracking recently used VREF levels, thereby requiring more aggressive read-disturbance management. Takeaway 2.The performance impact of read disturbance is generally worse under sequential- read workloads (which are considered best for SSD performance in a large body of work [42, 119– 121]) than under random-read workloads. From our later analysis, we focus on sequential-read pattern rather than random-read pattern, since read disturbance has a more significant impact on sequential-read performance.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:13 5.2 Impact of Read Ranges To better understand the read-disturbance management in modern SSDs, we perform the sequential- read tests while varying the read range from 64 MB to 50 GB, which would change the number of WLs and blocks repeatedly read during the test. We assume that all tested SSDs evenly dis- tribute incoming data across planes, which is common practice to fully leverage SSD-internal parallelism [65, 129, 130]. If our assumption holds, narrowing the read range to 64 MB or 256 MB limits the number of WLs repeatedly read within a block for all tested SSDs, whereas expanding the range to 25 GB or 50 GB leads multiple blocks to be disturbed during our sequential-read tests. Fig. 6 compares the per-second bandwidth of eight SSDs (SSD -B/-C/-D/-G/-J/-K/-L/-O) at early lifetime stage using box-and-whisker plots. We select the eight SSDs that represent each SSD group with the distinct characteristics and exhibit acceptable read-disturbance management overheads. We also plot the average bandwidth during the test ( ) and outliers (×) in Fig. 6. We make three key observations from Fig. 6. 64 MB256 MB1 GB25 GB50 GBRead Range: Bandwidth [GB/s] 0 84 (a) SSD-B(b) SSD-C(c) SSD-D(d) SSD-G(e) SSD-J(f) SSD-K(g) SSD-L(h) SSD-O Fig. 6. Read-bandwidth distribution with different read ranges. Observation 7.Most tested SSDs show similar performance for read ranges from 64 MB to 1 GB. Except for SSD-B and SSD-C (which will be discussed later in Observation 9), all SSDs exhibit largely consistent average bandwidth with variations smaller than 5.08% across the 64-MB, 256-MB, and 1-GB read ranges. In particular, the performance drop timings of SSD -G/-K/-O also hardly change with the read range (not directly shown in Fig. 6). The results strongly suggest that these SSDs perform read-disturbance management at theblocklevel, e.g., reclaiming a block when the block’s read count exceeds a threshold [131–133]. Observation 8.Most tested SSDs better perform with larger read ranges, e.g., 25 GB and 50 GB. Except for SSD-C and SSD-G (discussed later in Observation 9), all SSDs exhibit higher average bandwidth (SSD-B/-J/-K/-L/-O) and/or less performance fluctuations (SSD-B/-D/-J/-K/-L/-O) with the 25-GB and 50-GB read ranges compared to the small ranges. This result can be readily explained, as distributing read requests across a larger range would reduce per-block read disturbance over the same time window, postponing read disturbance-induced performance degradation. Note that, how- ever, when we extend the test time up to 3,000,000 seconds, all SSDs eventually incur performance drops even more significant than with the small read ranges, as they need to simultaneously perform read-disturbance management tasks for more blocks, which clearly shows that read disturbance and its management are inevitable in modern SSDs. Observation 9.A few SSDs exhibit distinct behaviors across the read ranges from other SSDs. Unlike other SSDs, SSD-B and SSD-C exhibit varying performance across the small (64-MB, 256-MB, and 1-GB) read ranges (opposite to Observation 7), and the average bandwidth of SSD-C and SSD-G significantly degrades with the larger read ranges (opposite to Observation 8). We further analyze theseoutlierSSDs with more comprehensive comparisons of performance variations depending on
10:14 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park the read range. Fig. 7 shows the read bandwidth of (a) SSD-B, (b) SSD-C, and (c) SSD-G, during 30,000-second sequential-read tests while varying read ranges from 64 MB to 50 GB. 8 04Bandwidth [GB/s] Time [103 seconds]302010 302010 302010(a) SSD-B (c) SSD-G(b) SSD-C Read Range:64 MB256 MB1 GB25 GB50 GB Time [103 seconds] Time [103 seconds] Fig. 7. Comparisons of sequential-read bandwidth across different read ranges in outlier SSDs. We observe that the three outlier SSDs operate significantly differently even compared to each other. First, SSD-B incurs more frequent performance drops with a smaller read range: four, two, and one drop(s) with 64-MB, 256-MB, and 1-GB read ranges during the test, respectively. The result implies that SSD-B is aware of the varying reliability impact of read disturbance within a block; prior studies have demonstrated that reading a WL disturbs its adjacent WLs more significantly compared to other WLs [6–8]. Repeated reads to only part of each block increase the RBER of the read WLs more rapidly compared to the others, thereby requiring more frequent management tasks for the WLs. We hypothesize that other SSDs perform read-disturbance managementmore conservatively, e.g., reclaiming an entire block even when some WLs can actually endure more read disturbance, which can minimize performance variations across the small read ranges. Second, SSD-C performs better with smaller read ranges, stably providing high bandwidth. In fact, SSD-C exhibitsuniqueperformance-drop patterns during the 1-GB sequential-read test; its bandwidth graduallyincreases from the beginningof the test until a drop occurs, whereas all other SSDs provide their peak bandwidth initially. We hypothesize that SSD-C progressively migrates frequently read pages to MLC/TLC regions, allowing the pages to provide higher read performance and endure more read disturbance than QLC pages. This would be effective for small read ranges, but it can cause frequent garbage collections due to migration, providing diminishing returns with larger read ranges as shown in Fig. 7(b). Third, like most other SSDs, SSD -G incurs less frequent performance drops with the 25-GB and 50-GB read ranges compared to the smaller ranges,but only during the first halfof the test; its performance fluctuation becomes more severe with the large ranges as the test continues. In particular, with the 50-GB read range, significant and periodic performance drops continue after around 16,000 seconds until the end of the test, where the read bandwidth fluctuates from 6.8 GB/s (sustained for 4–5 seconds) to 3.2 GB/s (for 5–7 seconds). During each drop period (i.e., 9– 12 seconds), SSD-G reads almost the same amount of data as the read range (i.e., 50 GB), and we confirm that specific regions consistently exhibit degraded bandwidth, similarly to Observation 4. We hypothesize that SSD-G periodically performs patrol reads to track the near-optimal VREF levels of stored pages to avoid read retry for future reads. Unfortunately, it is challenging to store the near- optimal VREF levels for every page due to the memory constraints, which limits the effectiveness of patrol reads when a large number of pages are continuously read. Takeaway 3.Even though various read-disturbance management techniques are employed across tested SSDs, there is no ultimate technique that operates optimally in all situations.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:15 5.3 Impact of PEC We analyze how the performance impact of read disturbance changes depending on the SSD-lifetime stage, i.e., the average PEC across blocks. To this end, we repeat the sequential-read tests with a 1-GB read range for eight SSDs at their middle ( >50%) and late ( >80%) lifetime stages. Fig. 8 compares the minimum, average, and maximum read-bandwidth values under the three lifetime stages (early:<20% of SSD lifetime). MaxAvgMinLifetime stage:EarlyMiddleLate8 0 4Bandwidth [GB/s]SSD-BSSD-CSSD-DSSD-GSSD-JSSD-KSSD-LSSD-O Fig. 8. Read bandwidth at different device lifetime stages. Observation 10.Read bandwidth generally decreases at later lifetime stages in all tested SSDs, but the degree of performance degradation varies across the SSDs. At the middle/late lifetime stages, most tested SSDs exhibit lower (i) average read bandwidth (by 11.2%/15.5% on average across SSD -C/-G/-J/-K/-L/-O) and/or (ii) minimum bandwidth (by 41.4%/54.5% on average across SSD-B/-C/-G/-K/-L), incurring more severe performance fluctuations than at the early stage. We also observe that the performance-drop patterns remain largely the same across the various SSD lifetime stages. Given their consistent peak bandwidth across lifetime stages, this result clearly shows that the performance impact of read disturbance increases with PEC. Interestingly, SSD-D and SSD-O provide similar performance regardless of their ages. We assume that these SSDs may (i) sustain the reliability of stored data by programming an aged block more precisely (e.g., programming data with wider VTH margins can significantly enhance the data’s reliability, but at the cost of increased program latency [134–138]), (ii) perform read-disturbance management conservatively even at early lifetime stages, or (iii) manufacturers conservatively set the PEC limit (i.e., SSD lifetime) before errors can significantly affect SSD performance. Takeaway 4.The performance impact of read disturbance increases with PEC in general, but proactive and conservative reliability management can mitigate such an effect. 5.4 Impact of SSD Idle Time We analyze how the performance impact of read disturbance changes in the presence of SSD idle times that can potentially be leveraged for SSD-internal management tasks. To this end, we repeat the same sequential-read test for all 15 SSDs while providing SSD idle times by issuing no I/O requests for a certain amount of time. Fig. 9 shows the read bandwidth of (a) SSD-B, (b) SSD-J, (c) SSD-K, and (d) SSD-L, when 6-hour idle time (vertical dotted lines) is given for every 10,000 seconds during the sequential-read test for 30,000 seconds with a 1-GB read range. Observation 11.Most tested SSDs show largely consistent performance-drop patterns even in the presence of long (six hours) SSD idle times.
10:16 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park Bandwidth [GB/s] Time [103 seconds] 302010 (b) SSD-J 302010 (c) SSD-K 8 04 (a) SSD-B302010 Idle Time (6 hours) 302010 (d) SSD-LTime [103 seconds]Time [103 seconds]Time [103 seconds] Fig. 9. Sequential-read test results with idle times. SSD idle times hardly change the performance-drop patterns of SSD-B/-J/-K/-L; all four SSDs fail to recover or maintain the initial read bandwidth after long idle times. We observe similar trends for all tested SSDs, which clearly shows that they performnobackground SSD-internal management tasks for read disturbance. Doing so leaves the SSDs suffering from performance degradation due to read disturbance, but can avoid other issues potentially caused by background tasks, such as (i) delaying future user I/Os, (ii) consuming additional energy, and (iii) increasing P/E cycles. Takeaway 5.Many modern SSDs donotproactively perform read-disturbance management using idle times, contrary to the common assumption that idle times would be utilized for various internal tasks [4, 9, 53, 59, 139–141]. 6 Case Study: SSD-Performance Attacks To emphasize the system-level performance impact of read disturbance, we showcase a new possible SSD-performance attack. Our key idea is to deliberately amplify read-disturbance management overheads, enabling an adversary to timely degrade the I/O performance of co-running applications that share the same SSD. We hypothesize that such a performance attack would be highly feasible, as commodity SSDsequallyschedule the I/O requests from different processes, regardless of the SSD-internal management overheads for each process [63, 112, 142, 143]; if an adversary maliciously exacerbates performance overheads, it would also affect the I/O performance of benign applications sharing the same SSD. There could be other ways simpler and/or more effective to degrade the I/O performance of co-running applications, e.g., issuing massive I/Os with more processes [144–148] or incurring garbage collection frequently via consistent writes [63, 148–150], but this work is the first to experimentally demonstrate that read disturbance can also be exploited for a storage-related denial-of-service(DoS) attack on commodity SSDs. 6.1 Attack Model We assume an adversary only with user-level access to the same SSD as target applications, but no capability to modify SSD firmware or escalate host-system privileges. We also assume that the host system limits the adversary’s SSD access in three aspects. First, to ensure data privacy, the host dedicates an exclusive LBA range of the shared SSD to each user, e.g., mounting multiple file systems on the SSD, which can avoid the adversary’s direct access to any data of target applications. Second, for performance isolation, the host limits the number of CPU cores available for each user, preventing the adversary from issuing excessive I/Os than other users. Third, to avoid premature SSD wear-out, the host restricts each user’s write traffic, hindering write-based SSD-performance attacks. For example, when an SSD supports 14,016 TBW (terabytes written) in total with a 5-year warranty [151], the maximum write rate to the SSD is limited to 91 MB/s.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:17 We assume that the adversary can meet the following two key requirements for successfully performing our proposed attack. First, the attacker can accurately measure the performance of I/O requests in their LBA space, which is necessary to prepare the attack. Second, the attacker can detect the execution of the target application to timely trigger the attack. 6.2 Attack Patterns Based on our observations in §5, we devise two attack patterns, both of which consist of two phases: (i)preparationand (ii)degradation. In general, both attacks accumulate read-disturbance to NAND flash blocks during the preparation phase to exaggerate the performance overheads of read-disturbance management techniques inside the SSD during the degradation phase. We aim to maximize performance degradation during the degradation phase while minimizing the time required for the preparation phase. Fig. 10 presents the high-level overview of the two attack patterns, called (a)Charge-and-Burst(CAB) and (b)Weak-Spot Focus(WSF), respectively. LBA Range of Adversary (a) Charge-and-BurstTime C1MCC2MC…Cn……READ C1C2Cn C2CnC11 2 ……READ RW1 3RW (b) Weak-Spot FocusTimeIdentify WLBA Range of Adversary READ W2…… Fig. 10. Overview of two attack patterns. Charge-and-Burst Pattern.The key idea of CAB is toconcentratethe periodic performance drops observed in our sequential-read test into a short time window. To this end, we 1 first accumulate (i.e.,charge up) read disturbance to multiple chunks (e.g., C 𝑘 in Fig. 10(a)) during the preparation phase, by repeating sequential reads on each chunk (one after the other) untilright beforea performance drop occurs. During the degradation phase, we 2 again repeat per-chunk sequential reads until a significant performance drop occurs and move to the next chunk immediately once the drop is over, whichburstsperformance drops with short intervals. For CAB-based attacks, it is crucial to timely terminate the preparation phase for each chunk; early termination defers a performance drop during the degradation phase, whereas late termination can cause a premature drop during the preparation phase. To address this, we employ two termination policies for the preparation phase; (i) if an SSD exhibits long drop durations (e.g., SSD-A and SSD -B), we stop the preparation phase of each chunk upon aslightperformance drop; (ii) otherwise, we limit the preparation-phase time to the minimum drop period observed in our profiling. To further reduce premature drops, we also reserve a margin after each chunk (e.g., MC in Fig. 10(a)), which is large enough to prevent different chunks from being stored in the same NAND flash block. Doing so ensures that reading a WL disturbs only one chunk’s data, thereby avoiding unintended performance drops at C𝑘 while reading C𝑘+1 during the preparation phase. Weak-Spot Focus Pattern.The key idea of Weak-Spot Focus (WSF) is tosustainsignificant performance drop by reading only aweak spot, i.e., a data region that causes higher reliability- management overhead than other regions (as in Observation 4). To this end, during the preparation phase, we 1 accumulate read disturbance by sequentially reading a large range of data (e.g., R in Fig. 10(b)) until identifying a weak spot that incurs performance drops (e.g., W in Fig. 10(b)). We then 2 concentrate sequential reads on the weak spot to accelerate read-disturbance accumulation. Once the read bandwidth degrades sufficiently, we 3 repeat sequential reads only to the weak spot during the degradation phase.
10:18 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park 6.3 Evaluation Methodology.Fig. 11 shows the high-level overview of our methodology to evaluate the effec- tiveness of the proposed attacks when two processes, attacker and victim, share the same SSD. Each of the two processes has access only to a contiguous and non-overlapping LBA range of the SSD (e.g., LA and LV in Fig. 11). To avoid unintended read disturbance to the victim’s data due to reading of the attacker’s data, we set a margin (e.g., ML in Fig. 11) between the two LBA ranges. The attacker first 1 enters the preparation phase, accumulating read disturbance by repeating sequential reads throughout its LBA range. Once the attacker detects 2 the victim’s execution, it 3 triggers the degradation phase. 2Victim Execution3Degradation Phase 1Preparation Phase…LA ML L V … AttackerDetect Fig. 11. Overview of proposed SSD-performance attack. We adaptively use the CAB and WSF patterns depending on the target SSD’s performance-drop characteristics as in Observation 3. We use the CAB pattern for SSDs that exhibit steep and periodic performance drops (SSD-A/-B/-D/-G/-J/-M) and the WSF pattern for SSDs that show consistent performance degradation over time in certain regions (SSD-G/-K/-L/-M). We identify that SSD-G and SSD-M meet both conditions, which allows us to use acombinedpattern; we first profile weak spots throughout a large LBA region and use them as candidate data chunks for a CAB-based attack. Table 3 summarizes the sizes of data chunks and ranges used in our evaluation of SSD-performance attacks. Note that the parameters used in our evaluation maynotbe optimal, as our goal in this case study is to emphasize the importance of better read-disturbance management in modern storage systems, butnotto develop or optimize the attacks themselves for practical deployment. Table 3. Summary of the parameters for the proposed SSD-performance attacks. Terminology Definition Size LA/LV LBA ranges of attacker/victim 150 GiB ML Margin between LA/LV 50 GiB C1–C5 Five data chunks used for CAB 32 MiB MC Margin between C𝑘 and C𝑘+1 5 GiB R Large data range used for WSF 50 GiB W Weak spot used for WSF 32 MiB Evaluation Results.To evaluate the effectiveness of our SSD-performance attacks, we compare the victim’s read bandwidth under two execution scenarios: co-running with (i) the attacker and (ii) another benign process. Both the victim and benign processes sequentially read their exclusive LBA range (150 GiB) at the pristine state, i.e., no read disturbance accumulated. To assess the proposed attack’s timeliness, we separate its preparation and degradation phases with an SSD idle time (> 1 hour). Fig. 12 shows the most representative results for (a) CAB-based attack (SSD-D), (b) WSF-based attack (SSD-L), and (c) combined attack (SSD-G) from our evaluation of all 15 tested SSDs at their late lifetime stages. We repeat each experiment three times and confirm that the
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:19 proposed performance attacks successfully and considerably degrade the victim’s read bandwidth in most tested SSDs: SSD -A/-B/-D/-G/-J/-M (CAB), SSD-G/-K/-L/-M/-O (WSF), and SSD -G/-M (combined). 90Time [seconds]3060 Bandwidth [GB/s] 4 02 (a) SSD-D 1,2003,600Time [seconds] SSD-L BenignVictim (w/ Attacker)AttackerVictim (w/ Benign) 306090Time [seconds] CAB (c) SSD-G WSF 1202,400 Fig. 12. Read bandwidth depending on co-running processes. Observation 12.Both our CAB- and WSF-based attacks can significantly degrade the I/O perfor- mance of the victim process, requiring neither reading the victim’s data nor issuing writes. As shown in Fig. 12(a), the CAB-based attack on SSD-D causes significant performance drops five times (i.e., at all chunks C1 to C5) within 90 seconds, each degrading the victim’s read bandwidth by 74.8% for 3 seconds on average. Given that the average drop period observed during our entire sequential-read tests on SSD-D is >2,000 seconds, the result clearly demonstrates the CAB-based attack’s capability to burst performance drops. It is possible to induce more performance drops by using more chunks, but this comes at the cost of longer preparation phase. The WSF-based attack also significantly affects the victim’s I/O performance, but in a different way from the CAB-based attack. As shown in Fig. 12(b), the attack on SSD-L consistentlydegrades the read bandwidth of the victim process by 54.2% on average during the entire degradation phase that we limit to 3,600 seconds. We expect that the WSF-based attack can affect the victim’s I/O performance even for several hours regardless of idle time, given that all Type -2 SSDs cannot recover the read bandwidth of weak spots during the sequential-read test for 30,000 seconds. Observation 13.The CAB and WSF patterns can be synergistically combined to devise a more severe SSD-performance attack that further degrades the victim’s I/O performance. As shown in Fig. 12(c), using the weak spots prepared by the WSF pattern enables the attacker process to limit the victim’s read bandwidth to around 2 GB/s (40.9% lower than the no-attack baseline) during the degradation phase. In the meantime, the attacker also successfully causes further performance drops by 70.4% at all five weak spots with the CAB pattern. Note that the attacker can skip the WSF pattern’s preparation phase for future combined attacks as long as the used weak spots remain degraded (≥30,000 seconds in our sequential-read test). Observation 14.Two concurrent processes show almostidenticalperformance in all three SSDs. As shown in Fig. 12, the victim’s read bandwidth closely tracks that of the concurrently running process (attacker or benign) with minimal deviation. We observe the same trend in all 15 tested SSDs, which validates our hypothesis; the common I/O-scheduling policy in modern SSDs makes our proposed performance attacks highly feasible byunfairlyforcing the victim process to suffer half of the attacker-induced slowdown.
10:20 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park Takeaway 6.Under the common I/O-scheduling policy in modern SSDs, an application’s I/O performance can degrade when it shares the same SSD with other read-intensive applications, much more significantly than expected. 7 Macro-Benchmark Evaluation Although our primary goal in this work is to analyze the system-level performance impact of read disturbancewhen it is substantial(e.g., under heavily read-dominant workloads), we also evaluate read–write mixed macro-benchmarks to understand the impact in more general cases. 7.1 Methodology Workloads.We use theweb serverandvideo serverworkloads from the FileBench benchmark tool [152] with the direct I/O option, both maintaining separate file sets for read and write operations. Theweb serverworkload consists of multiple threads, each of which randomly reads several files from the data-file set and then appends data to a single shared log file. Thevideo serverworkload comprises two types of threads: (i) multiple reader threads, which randomly read files from the active file set, and (ii) a single writer thread, which periodically deletes a file from the passive file set and writes a new file to it. Table 4 summarizes the key characteristics of the workloads used in our evaluation. We adjust each workload to vary the read-write ratio by configuring (i) the number of files read per log update to five (write-heavy) and ten (read-heavy) forweb serverand (ii) the file-replacement interval to one second (write-heavy) and ten seconds (read-heavy) forvideo server. The defaultweb server workload monotonically increases the log file’s size, quickly exhausting the entire SSD capacity and thus preventing long-term evaluation. To address this, we introduce a log-backup process that truncates the entire log file after copying it to another storage device periodically (every 15 and 20 minutes for write-heavy and read-heavy workloads, respectively). Table 4. FileBench workload characteristics. Workload File set type Average file size Number of files I/O sizes Number of threads Read/Write ratioRead Write Web Server Data 16 KB 65,536 16 KB – 100 WH1: 5:1 RH2: 10:1Log 1 – 16 KB Video Server Active 1 GB 10 1 MB – 33 WH: 4.6–40:1 RH: 33–44:1Passive 432 – 1 MB 1 1WH: Write-heavy, 2RH: Read-heavy. Preconditioning.We precondition both the file system and SSD before each FileBench experiment in three steps to reduce potential distortions caused by previous device and file system states. First, we delete all files under the target mount point to reset the file-system namespace. Second, we issue a TRIM command to the mount point to inform the SSD of invalidated LBAs via the fstrim command. Third, we disable address space layout randomization (ASLR), as some SSDs do not operate reliably under randomized memory layouts during FileBench test. All experiments run on the ext4 file system, and we monitor SSD performance using the Linuxiostattool. 7.2 Evaluation Results Fig. 13 shows the read and write bandwidth of (a) SSD-B, (b) SSD-C, (c) SSD-J, (d) SSD-L, and (e) SSD -M during FileBench test for 30,000 seconds. For thevideo serverworkloads, we denote the actual
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:21 read-write ratio (R/W), which varies depending on the SSD’s request scheduling policy; unlike in web serverwhere each thread performs both read and write operations, threads invideo server perform either read or write operations only, so the amounts of reads and writes actually performed highly depend on how the SSD schedules I/Os from different threads. Note that most tested SSDs exhibit periodic read-bandwidth spike inweb server, which occurs during the log-backup process, i.e., sequential reading of the entire log filewithoutread disturbance or write-induced interference. Video Server (RH, R/W: 44.7)5 02.5 Video Server (WH, R/W: 27.2)5 02.5 Web Server (RH)5 02.5 Web Server (WH)5 02.5Bandwidth [GB/s]Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30(a) SSD-B Video Server (RH, R/W: 45.5)5 02.5 Video Server (WH, R/W: 39.8)5 02.5 Web Server (RH)5 02.5 Web Server (WH)5 02.5Bandwidth [GB/s]Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30(b) SSD-C Video Server (RH, R/W: 39.6)5 02.5 Video Server (WH, R/W: 29.4)5 02.5 Web Server (RH)5 02.5 Web Server (WH)5 02.5Bandwidth [GB/s]Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30(c) SSD-J Video Server (RH, R/W: 42.4)5 02.5 Video Server (WH, R/W: 30)5 02.5 Web Server (RH)5 02.5 Web Server (WH)5 02.5Bandwidth [GB/s]Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30(d) SSD-L Video Server (RH, R/W: 30.6)5 02.5 Video Server (WH, R/W: 4.6)5 02.5 Web Server (RH)5 02.5 Web Server (WH)5 02.5Bandwidth [GB/s]Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30Time [103 seconds]2010 30(e) SSD-M Write BandwidthRead Bandwidth Fig. 13. FileBench test results. Observation 15.In many cases, the performance impact of read disturbance becomes less severe under read-write mixed workloads compared to read-only workloads. SSD-B exhibits only a single severe performance drop that we suspect is caused by read disturbance, i.e., near-zero read-bandwidth lasting 2 seconds at 21,236 seconds under the read-heavyweb server workload, which is too infrequent to be attributed to garbage collection. Under all FileBench workloads, SSD-J does not exhibit the significant performance fluctuations observed under the read- only workloads. Similarly, under theweb serverworkloads issuing a number of small random reads,
10:22 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park SSD-L and SSD-M do not experience the performance fluctuations observed under the random-read tests (cf. Figs. 5(l) and 5(m)). The results are largely expected and can be readily explained by the fact that writes are well known to affect SSD performance more severely than reads, due to the long program latency of NAND flash memory and various write-related FTL tasks, such as garbage collections and wear leveling. Write-induced degradation of overall I/O bandwidth can decrease the performance impact of read disturbance in two ways. First, the substantial performance impact of writes dominates overall SSD performance, thereby making the relative impact of read disturbance less pronounced. Second, it slows down the accumulation of read disturbance, which, in turn, reduces the frequency of read-disturbance-induced reliability management tasks. Observation 16.In some SSDs, read disturbance can have a non-trivial impact on I/O performance under read-write mixed workloads. We observe that SSD-C exhibits consistent peak-performance degradation under all FileBench workloads, unlike the behavior we observe under read-only workloads, where it can periodically recover its peak bandwidth (cf. Figs. 3(c) and 5(c)). In particular, significant performance fluctuations occur after 20,000 seconds under thevideo serverworkloads, which are also not observed under any read-only workloads. As explained in §5.2 (Observation 9), we hypothesize that SSD-C proactively migrates read-hot data to other physical blocks; unfortunately, such migration becomes difficult in the presence of user writes, causing accumulated read disturbance to consistently affect SSD performance. We also observe continuous performance drops over time in SSD-L and SSD-M under thevideo serverworkloads, similarly under sequential read workloads (cf. Figs. 3(l) and 3(m)). Under the read-heavy (write-heavy)video serverworkload, SSD -L and SSD-M exhibit considerable read-bandwidth reductions of 55.9% (57.8%) and 22.5% (19.8%), respectively, when comparing the last five minutes to the first five minutes. Note that the performance drops in SSD-L and SSD-M undervideo serverdiffer from those observed in SSD -B/-J/-L/-M underweb server. We attribute the performance drops underweb serverto SLC-buffer flushes, as the workloads initially write only a limited amount of data (≈1 GB). In contrast, thevideo serverworkloads rapidly exhaust the SLC buffer at the beginning by sequentially writing the large passive file set, making it plausible that read disturbance is the root cause of the continuous performance drops. Takeaway 7.The performance impact of read disturbance is generally reduced in the presence of write requests, but read disturbance can still introduce non-trivial performance degradation in some operating scenarios (SSDs and workloads). 8 Implications Our observations made in §5 and §6 can guide host- and SSD-side future improvements for modern storage systems to enhance I/O performance for read-intensive applications. We leave the develop- ment of new techniques for such improvements to future work, which can benefit from not only our guidance but also observations that we make on the behavior of read-disturbance management techniques applied in commodity SSDs (e.g., for developing a more accurate SSD simulator that can model more realistic SSD performance). 8.1 Host-Side Improvements Our characterization study can help system designers and application developers improve the I/O performance of their systems and applications, respectively, in two ways. Better Understanding of System I/O Performance.Observations 1 to 5 demonstrate that theactualSSD performance under read disturbance varies across SSDs and differs from vendor
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:23 specifications. A deeper understanding of such actual performance characteristics can allow more efficient system and application design in two ways. First, system designers can better provision storage resources to meet their performance requirements at minimal cost, selecting the appropriate SSD model and quantity to ensure that storage systems offer the desired performance under the expected read patterns of critical applications. Second, application developers can better coordinate tightly coupled compute and data-access tasks. For example, a large language model (LLM) inference framework that relies on timely I/O prefetching [119, 153, 154] can achieve higher effectiveness through precise pipelining based on more accurate performance estimation. Host-SSD Interaction for Better Read-Disturbance Management.Observations 4, 11, and 12 show that read disturbance-induced I/O slowdown may remain indefinitely even with sufficient SSD idle times. To recover I/O performance for critical data, an application itself needs to rewrite the data (after reading it) to the SSD. Even though the application can accurately determine the timing and target data for read reclaim, such application-managed read-disturbance management can cause non-trivial inefficiencies due to costly host-SSD data movements. Such inefficiencies can be addressed by introducing anew storage interfacethat enables the host to proactively trigger read reclaim on target data, similarly to NVMe I/O determinism (IOD) [155]. Currently, IOD allows the host to temporarily forbid SSD-internal management tasks, but it offers no mechanism for the host to proactively trigger those tasks or specify their target data. We expect that the development of such an interface can accurately inform SSDs of when read reclaim is needed and be further extended to allow the host to specify data to be stored in a more reliable region which is less susceptible to read disturbance (e.g., SLC/MLC blocks or robust WLs that provide better reliability). 8.2 SSD-Side Improvements Our characterization study can be used in four ways for developing efficient FTL algorithms to better manage read disturbance inside SSDs. Proactive Read-Disturbance Management.Observations 3, 9, and 10 highlight the importance of proactive read-disturbance management. As observed, excessive delay of read reclaim can rather cause significant long-term performance degradation or severe performance fluctuation when multiple blocks require read reclaim simultaneously, contrary to common practice of deferring read reclaim until truly necessary to minimize its high impact on application performance [ 5]. In particular, the effectiveness of proactive management can be further improved by taking into account the lifetime of blocks; increasing proactivity for aged blocks can effectively mitigate read-retry and ECC overheads that worsen at high PEC. Mitigating Performance Fluctuation due to Read-Disturbance Management.Observa- tions 3, 11, and 12 suggest three directions to avoid severe performance drops due to proactive read-disturbance management. First, we can minimize the performance impact of proactive man- agement by efficiently utilizing over-provisioned parallelism while prioritizing user I/Os. Second, leveraging SSD idle time can possibly eliminate user-experienced performance drops. Third, read- disturbance management should be performed in aprogressivemanner, i.e., reclaiming a few blocks preemptively rather than reclaiming a number of blocks at once. Adaptive Read-Disturbance Management.Observations 6 and 9 suggest that read-disturbance management should take workload I/O patterns into account in two aspects. First, read reclaim should be prioritized for data accessed sequentially over data referenced randomly since read disturbance has less impact under random reads compared to sequential reads. Second, promoting read-intensive datato SLC or MLC regions, which are less susceptible to read disturbance, can effectively mitigate the performance overhead of read-disturbance management. Such promotion must be performed carefully, as it involves substantial data movements across different regions, which can negatively affect SSD performance as shown in Fig. 7 (b).
10:24 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park Read Disturbance-Aware Internal I/O Scheduling.Observations 12 to 14 suggest that the SSD controller should isolate internal I/O traffic related to read-disturbance management to minimize their interference with other processes. Most SSDs prioritize fairness by equally scheduling I/O requests from concurrently running processes, without distinguishing read disturbance-related reads and writes. As a result, I/O requests from other users are often delayed, leading to significant performance degradation. For better performance isolation, the FTL should be able to track the processes that trigger read-disturbance management and impose such overheads only on the corresponding processes. 9 Related Work To our knowledge, this work is the first to rigorously characterize the system-level performance impact of read disturbance in modern SSDs under various operating conditions, which introduces new observations and takeaways related to read-disturbance management techniques, e.g., their impact depending on workloads, idle times, and co-running processes. We provide a brief review of prior studies on read-disturbance characterization and mitigation. Read-Disturbance Characterization.In addition to the prior work [ 5] that we already discussed in §3, many other previous studies have also investigated the reliability impact of read disturbance in NAND flash memory under various multi-leveling techniques, including MLC [9], TLC [8, 10, 156], and QLC [157]. Although these studies conduct extensive analyses of read disturbance, their scope is limited to the device level rather than the system level. In contrast, our work characterizes the system-level performance impact of read disturbance, providing deeper insights for designing both host systems and SSD architectures to develop more effective read-disturbance management. Read-Disturbance Mitigation.Prior studies [ 4, 9] have proposed device-level techniques to mitigate the reliability impact of read disturbance. Cai et al. [9] propose a new page-read mechanism of NAND flash memory that uses a lower V PASS level to reduce the V TH shift caused by read disturbance. Even though the lower VPASS level slightly increases RBER for the highest VTH state (e.g., P7 in TLC NAND flash memory), its benefit (i.e., reducing read disturbance) outweighs the cost, thereby leading to an overall RBER improvement. Ha et al. [4] propose to narrow the VTH window of a block via more precise programming, allowing the use of a lower VPASS level without RBER increases for the highest VTH state. They minimize the performance penalty of precise programming by selectively storing only read-intensive data to more robust blocks with a narrower VTH window. Read-Reclaim Optimization.Several prior studies [ 4, 6, 23, 133, 158] have proposed various firmware-level techniques to mitigate the overheads of read reclaim, the reliability-management task directly related to read disturbance. Ha et al. [4] propose a new data-placement technique that places read-intensive data to pages that require fewer sensing operations (e.g., LSB/MSB pages in Fig. 2), which effectively mitigates read disturbance per page read, thereby reducing read-reclaim invocations. Zhang et al. [23] also introduce another data-placement scheme that mixes read-hot and read-cold data within the same block to avoid concentrating reads on the specific blocks and thus reduces read reclaims triggered by the same number of page reads. Han et al. [133] employ different read-count thresholds for read reclaim depending on the page types, which enables a block to service more page reads before migrating the block’s disturbed data. Two recent studies aim to minimize data migration via more fine-grained read reclaim at low cost; Chun et al. [ 6] leverage the Space-Saving algorithm to efficiently estimate the read disturbance accumulated to each WL, and Lee et al. [158] optimize the patrol-read mechanism to accurately monitor the RBER of WLs with minimal performance overheads. Other Optimizations for Reliability-Management Techniques.A large body of prior work has proposed various techniques to optimize read retry and ECC, which can also mitigate the
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:25 performance impact of read disturbance. First, many studies have extensively optimized the read- retry mechanism. Shim et al. [101] propose a new read mechanism that reuses VREF levels recently used for neighboring WLs to reduce the number of read retries, which we assume are used in SSD-G and SSD-M. Park et al. [21] develop a new read-retry mechanism that reduces the latency of a read-retry operation by leveraging the large ECC margin and the cache-read feature. Chun et al. [ 22] introduce an on-die read-retry mechanism that performs read retry inside the chip without ECC decoding, thereby significantly improving effective utilization of internal-channel bandwidth. Ye et al. [24] try to predict optimal VREF value based on (i) page type, (ii) P/E cycles, and (iii) retention time. Second, some studies [159–161] have proposed various ECC algorithms and hardware decoder designs to enhance error-correction capability and decoding throughput. Our work is aligned with these efforts but goes a step further in three key aspects. First, although prior studies have achieved substantial improvements in mitigating the performance impact of read disturbance, our experimental studies using commodity SSDs demonstrate that read disturbance is a fundamental problem that is difficult to completely eliminate. Second, we identify the potential risk of DoS attacks that exploit read disturbance as a vulnerability and experimentally demonstrate their impact on modern SSDs, which highlights the need to develop new techniques to mitigate performance interference caused by read disturbance in multi-tenant scenarios. Third, based on our characterization results, we present new optimization directions at the host and interface levels. 10 Conclusion In this study, we investigate the system-level performance impact of read disturbance in modern SSDs, which remains largely uninvestigated by prior studies. Through extensive experiments on 15 NVMe SSDs, we demonstrate how significantly read disturbance can degrade I/O performance and even be exploited for potential DoS attacks. Our 16 observations and 7 takeaway lessons lead to six key directions for improving host-system and SSD-architecture design, emphasizing the need for more integrated and proactive read-disturbance management. We hope that the novel experimental results and insights of our study will inspire and aid future work to develop more effective read-disturbance management techniques. Acknowledgments We thank our anonymous reviewers of SIGMETRICS 2026 for their valuable feedback and com- ments. This work was supported by the National Research Foundation of Korea (RS-2023-00283799, RS-2024-00396850, RS-2024-00415602, and RS-2025-00519994), Institute for Information & Com- munications Technology Planning & Evaluation (RS-2024-00347394 and RS-2024-00437866), and Samsung Electronics Co., Ltd (IO230411-05858-01). Jisung Park is the corresponding author. References [1] Sungdae Choi, Duckju Kim, Sungwook Choi, Byungryul Kim, Sunghyun Jung, Kichang Chun, Namkyeong Kim, Wanseob Lee, Taisik Shin, Hyunjong Jin, Hyunchul Cho, Sunghoon Ahn, Yonghwan Hong, Ingon Yang, Byoungyoung Kim, Pilseon Yoo, Youngdon Jung, Jinwoo Lee, Jaehyeon Shin, Taeyun Kim, Kunwoo Park, and Jinwoong Kim. A 93.4mm2 64Gb MLC NAND-Flash Memory with 16nm CMOS Technology. InProceedings of the 2014 IEEE International Solid-State Circuits Conference (ISSCC), 2014. [2] Wontaeck Jung, Hyunggon Kim, Do-Bin Kim, Tae-Hyun Kim, Namhee Lee, Dongjin Shin, Minyoung Kim, Youngsik Rho, Hun-Jong Lee, Yujin Hyun, Jaeyoung Park, Taekyung Kim, Hwiwon Kim, Gyeongwon Lee, Jisang Lee, Joonsuc Jang, Jungmin Park, Sion Kim, Su Chang Jeon, Suyong Kim, Jung-Ho Song, Min-Seok Kim, Taesung Lee, Byung- Kwan Chun, Tongsung Kim, Young Gyu Lee, Hokil Lee, Soowoong Lee, Hwaseok Lee, Dooho Cho, Sang-Wan Nam, Yeomyung Kim, Kunyong Yoon, Yoonjae Lee, Sunghoon Kim, Jungseok Hwang, Raehyun Song, Hyunsik Jang, Jaeick Son, Hongsoo Jeon, Myunghun Lee, Mookyung Lee, Kisung Kim, Eungsuk Lee, Myeongwoo Lee, Sungkyu Jo, Chan Ho Kim, Jong Chul Park, Kyunghwa Yun, Soonock Seol, Ji-Ho Cho, Seungjae Lee, Jin-Yub Lee, and Sung-Hoi Hur. A
10:26 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park 280-Layer 1Tb 4b/cell 3D-NAND Flash Memory with a 28.5Gb/mm2 Areal Density and a 3.2GB/s High-Speed IO Rate. InProceedings of the 2024 IEEE International Solid-State Circuits Conference (ISSCC), 2024. [3] Samsung. Samsung BM1743, 2024. https://semiconductor.samsung.com/news-events/tech-blog/samsung-ushers-in- the-ai-revolution-with-memory-and-storage-solutions-for-ultra-high-capacity-and-performance-at-fms-2024/. [4] Keonsoo Ha, Jaeyong Jeong, and Jihong Kim. An Integrated Approach for Managing Read Disturbs in High-Density NAND Flash Memory.IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems (TCAD), 2016. [5] Chun-Yi Liu, Yunju Lee, Myoungsoo Jung, Mahmut Taylan Kandemir, and Wonil Choi. Prolonging 3D NAND SSD Lifetime via Read Latency Relaxation. InProceedings of the 26th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2021. [6] Myoungjun Chun, Jaeyong Lee, Inhyuk Choi, Jisung Park, Myungsuk Kim, and Jihong Kim. STRAW: A Stress-Aware WL-Based Read Disturbance Management for High-Density NAND Flash Memory. InProceedings of the 31st ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2026. [7] Qin Xiong, Fei Wu, Zhonghai Lu, Yue Zhu, You Zhou, Yibing Chu, Changsheng Xie, and Ping Huang. Characterizing 3D Floating Gate NAND Flash: Observations, Analyses, and Implications.ACM Transactions on Storage (ToS), 2018. [8] Tiayu Ren, Qiao Li, Min Ye, and Chun Jason Xue. Read Disturb and Reliability: The Complete Story for 3D CT NAND Flash. InProceedings of the 2023 IEEE 12th Non-Volatile Memory Systems and Applications Symposium (NVMSA), 2023. [9] Yu Cai, Yixin Luo, Saugata Ghose, and Onur Mutlu. Read Disturb Errors in MLC NAND Flash Memory: Characteriza- tion, Mitigation, and Recovery. InProceedings of the 45th Annual IEEE/IFIP International Conference on Dependable Systems and Networks (DSN), 2015. [10] Cristian Zambelli, Piero Olivo, Luca Crippa, Alessia Marelli, and Rino Micheloni. Uniform and Concentrated Read Disturb Effects in Mid-1X TLC NAND Flash Memories for Enterprise Solid State Drives.Proceedings of the 2017 IEEE International Reliability Physics Symposium (IRPS), 2017. [11] Meng, Qingru. Read Disturb Management Improvement in SSDs, 2019. https://files.futurememorystorage.com/proce edings/2019/08-07-Wednesday/20190807_TEST-202A-1_Meng.pdf. [12] Jisung Park, Jaeyong Jeong, Sungjin Lee, Youngsun Song, and Jihong Kim. Improving Performance and Lifetime of NAND Storage Systems Using Relaxed Program Sequence. InProceedings of the 53rd ACM/EDAC/IEEE Design Automation Conference (DAC), 2016. [13] Myungsuk Kim, Jaehoon Lee, Sungjin Lee, Jisung Park, and Jihong Kim. Improving Performance and Lifetime of Large-Page NAND Storages Using Erase-Free Subpage Programming. InProceedings of the 54th ACM/EDAC/IEEE Design Automation Conference (DAC), 2017. [14] Yu Cai, Saugata Ghose, Yixin Luo, Ken Mai, Onur Mutlu, and Erich F. Haratsch. Vulnerabilities in MLC NAND Flash Memory Programming: Experimental Analysis, Exploits, and Mitigation Techniques. InProceedings of the 2017 IEEE International Symposium on High Performance Computer Architecture (HPCA), 2017. [15] Yu Cai, Onur Mutlu, Erich F. Haratsch, and Ken Mai. Program Interference in MLC NAND Flash Memory: Characteri- zation, Modeling, and Mitigation. InProceedings of the IEEE 31st International Conference on Computer Design (ICCD), 2013. [16] Kyoji Mizoguchi, Tomonori Takahashi, Seiichi Aritome, and Ken Takeuchi. Data-Retention Characteristics Comparison of 2D and 3D TLC NAND Flash Memories. In2017 IEEE International Memory Workshop (IMW). IEEE, 2017. [17] Shaoqi Yang, Meng Zhang, Xuepeng Zhan, Peng Guo, Xiaohuan Zhao, Guangkuo Yang, Xinyi Guo, Jixuan Wu, Fei Wu, and Jiezhi Chen. Retention accelerated testing for 3d qlc nand flash memory: Characterization, analysis, and modeling.IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems (TCAD), 2025. [18] Ren-Shuo Liu, Chia-Lin Yang, and Wei Wu. Optimizing NAND flash-based SSDs via retention relaxation.Target, 2012. [19] Yixin Luo, Saugata Ghose, Yu Cai, Erich F. Haratsch, and Onur Mutlu. Improving 3D NAND Flash Memory Lifetime by Tolerating Early Retention Loss and Process Variation.Proceedings of the ACM on Measurement and Analysis of Computing Systems (POMACS), 2018. [20] Robert Frickey, Joseph Doller, Robert Norton, Roman Sancho, Rakhshanda Sayyad, Dmitry Ustinov, Raymond Wang, and Harvey Xu. Comparing the Reliability of Solid-State Drives Based on TLC and QLC NAND Flash Memories. In Proceedings of the 2024 IEEE International Reliability Physics Symposium (IRPS). IEEE, 2024. [21] Jisung Park, Myungsuk Kim, Myoungjun Chun, Lois Orosa, Jihong Kim, and Onur Mutlu. Reducing solid-state drive read latency by optimizing read-retry. InProceedings of the 26th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2021. [22] Myoungjun Chun, Jaeyong Lee, Myungsuk Kim, Jisung Park, and Jihong Kim. RiF: Improving Read Performance of Modern SSDs Using an On-Die Early-Retry Engine. InProceedings of the 2024 IEEE International Symposium on High-Performance Computer Architecture (HPCA), 2024. [23] Genxiong Zhang, Yuhui Deng, Yi Zhou, Shujie Pang, Jianhui Yue, and Yifeng Zhu. Cocktail: Mixing Data with Different Characteristics to Reduce Read Reclaims for NAND Flash Memory.IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems (TCAD), 2022.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:27 [24] Min Ye, Qiao Li, Yina Lv, Jie Zhang, Tianyu Ren, Daniel Wen, Tei-Wei Kuo, and Chun Jason Xue. Achieving Near-Zero Read Retry for 3D NAND Flash Memory. InProceedings of the 29th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2024. [25] Samsung. Samsung 980 Pro, 500 GB, 2020. https://www.samsung.com/us/computing/memory-storage/solid-state- drives/980-pro-pcie-4-0-nvme-ssd-500gb-mz-v8p500b-am/. [26] Samsung. Samsung PM9A1, 512 GB, 2020. https://semiconductor.samsung.com/ssd/pc-ssd/pm9a1/. [27] Western Digital. WD Black SN850, 500 GB, 2020. https://documents.westerndigital.com/content/dam/doc-library/en_u s/assets/public/western-digital/product/internal-drives/wd-black-ssd/data-sheet-wd-black-sn850-nvme-ssd.pdf. [28] Seagate. Seagate FireCuda 530, 500 GB, 2021. https://www.seagate.com/www-content/datasheets/pdfs/firecuda-530- ssd-DS2059-1-2106US-en_US.pdf. [29] Micron. Micron 3400, 512 GB, 2021. https://assets.micron.com/adobe/assets/urn:aaid:aem:b1ec169c-b345-4593-a2da- 3a3b2a94eca0/renditions/original/as/micron-3400-ssd-product-brief.pdf. [30] Kingston. Kingston FURY Renegade, 512 GB, 2021. https://www.kingston.com/unitedkingdom/en/ssd/gaming/kings ton-fury-renegade-nvme-m2-ssd. [31] Hynix. SK Hynix Platinum P41, 500 GB, 2022. https://ssd.skhynix.com/platinum_p41/. [32] Crucial. Crucial P3 Plus, 500 GB, 2022. https://uk.crucial.com/products/ssd/crucial-p3-plus-ssd. [33] Micron. Micron 2400, 512 GB, 2022. https://assets.micron.com/adobe/assets/urn:aaid:aem:2573ba72-0b2a-4aa6-9a93- c75035939bc8/renditions/original/as/2400-ssd-product-brief.pdf. [34] Solidigm. Solidigm P41 Plus, 512 GB, 2023. https://www.solidigm.com/products/client/plus-series/p41.html#form=M .2%202280&cap=512%20GB. [35] HP. HP FX900 Pro, 512 GB, 2021. https://hp.biwintech.com/u_file/photo/20230822/FX900%20Pro%20Specifications.pdf. [36] Solidigm. Solidigm P44 Pro, 512 GB, 2023. https://www.solidigm.com/products/client/pro-series/p44.html. [37] Kioxia. Kioxia XG8, 512 GB, 2022. https://europe.kioxia.com/content/dam/kioxia/shared/business/ssd/client- ssd/asset/productbrief/cSSD-XG8-product-brief.pdf. [38] Crucial. Crucial T500, 500 GB, 2023. https://www.crucial.com/ssd/t500/ct500t500ssd8. [39] HP. HP FX700, 512 GB, 2023. https://hp.biwintech.com/products/hpfx700pciem.2ssd/. [40] Yang Hu, Hong Jiang, Dan Feng, and Lei Tian. Exploring and Exploiting the Multilevel Parallelism Inside SSDs for Improved Performance and Endurance.IEEE Transactions on Computers (TC), 2013. [41] Bo Mao, Suzhen Wu, and Lide Duan. Improving the SSD Performance by Exploiting Request Characteristics and Internal Parallelism.IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems (TCAD), 2018. [42] Nika Mansouri Ghiasi, Jisung Park, Harun Mustafa, Jeremie Kim, Ataberk Olgun, Arvid Gollwitzer, Damla Senol Cali, Can Firtina, Haiyu Mao, Nour Almadhoun, Rachata Ausavarungnirun, Nandita Vijaykumar, Mohammed Alser, and Onur Mutlu. GenStore: A High-Performance In-Storage Processing System for Genome Sequence Analysis. InProceedings of the 27th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2022. [43] Dongku Kang, Minsu Kim, Su Chang Jeon, Wontaeck Jung, Jooyong Park, Gyosoo Choo, Dong kyo Shim, Anil Kavala, Seung-Bum Kim, Kyung-Min Kang, Jiyoung Lee, Kuihan Ko, Hyun-Wook Park, Byung-Jun Min, Changyeon Yu, Sewon Yun, Nahyun Kim, Yeonwook Jung, Sungwhan Seo, Sunghoon Kim, Moo Kyung Lee, Joo-Yong Park, James C. Kim, Young San Cha, Kwangwon Kim, Youngmin Jo, Hyunjin Kim, Youngdon Choi, Jindo Byun, Ji hyun Park, Kiwon Kim, Tae-Hong Kwon, Youngsun Min, Chiweon Yoon, Youngcho Kim, Dong-Hun Kwak, Eungsuk Lee, Wook ghee Hahn, Ki sung Kim, Kyungmin Kim, Euisang Yoon, Won-Tae Kim, Inryoul Lee, Seung hyun Moon, Jeongdon Ihm, Dae Seok Byeon, Ki-Whan Song, Sangjoon Hwang, and Kye Hyun Kyung. 512gb 3-bit/cell 3d 6th-generation v-nand flash memory with 82mb/s write throughput and 1.2 gb/s interface. InProceedings of the 2019 IEEE International Solid-State Circuits Conference (ISSCC), 2019. [44] Tsutomu Higuchi, Takuyo Kodama, Koji Kato, Ryo Fukuda, Naoya Tokiwa, Mitsuhiro Abe, Teruo Takagiwa, Yuki Shimizu, Junji Musha, Katsuaki Sakurai, Jumpei Sato, Tetsuaki Utsumi, Kazuhide Yoneya, Yasuhiro Suematsu, Toshi- fumi Hashimoto, Takeshi Hioka, Kosuke Yanagidaira, Masatsugu Kojima, Junya Matsuno, Kei Shiraishi, Kensuke Yamamoto, Shintaro Hayashi, Tomoharu Hashiguchi, Kazuko Inuzuka, Akio Sugahara, Mitsuaki Honma, Keiji Tsun- oda, Kazumasa Yamamoto, Takahiro Sugimoto, Tomofumi Fujimura, Mizuki Kaneko, Hiroki Date, Osamu Kobayashi, Takatoshi Minamoto, Ryoichi Tachibana, Itaru Yamaguchi, Juan Lee, Venky Ramachandra, Srinivas Rajendra, Tianyu Tang, Siddhesh Darne, Jiwang Lee, Jason Li, Toru Miwa, Ryuji Yamashita, Hiroshi Sugawara, Naoki Ookuma, Masahiro Kano, Hiroyuki Mizukoshi, Yuki Kuniyoshi, Mitsuyuki Watanabe, Kei Akiyama, Hirotoshi Mori, Akira Arimizu, Yoshito Katano, Masakazu Ehama, Hiroshi Maejima, Koji Hosono, and Masahiro Yoshihara. A 1Tb 3b/cell 3D-Flash Memory in a 170+ Word-Line-Layer Technology. InProceedings of the 2021 IEEE International Solid-State Circuits Conference (ISSCC), 2021. [45] Moosung Kim, Sung Won Yun, Jungjune Park, Hyun Kook Park, Jungyu Lee, Yeong Seon Kim, Daehoon Na, Sara Choi, Youngsun Song, Jonghoon Lee, Hyunjun Yoon, Kangbin Lee, Byunghoon Jeong, Sanglok Kim, Junhong Park,
10:28 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park Cheon An Lee, Jaeyun Lee, Jisang Lee, Jin Young Chun, Joonsuc Jang, Younghwi Yang, Seung Hyun Moon, Myunghoon Choi, Wontae Kim, Jungsoo Kim, Seokmin Yoon, Pansuk Kwak, Myunghun Lee, Raehyun Song, Sunghoon Kim, Chiweon Yoon, Dongku Kang, Jin-Yub Lee, and Jaihyuk Song. A 1Tb 3b/Cell 8th-Generation 3D-NAND Flash Memory with 164MB/s Write Throughput and a 2.4 Gb/s Interface. InProceedings of the 2022 IEEE International Solid-State Circuits Conference (ISSCC), 2022. [46] ONFI Workgroup. ONFI 5.0 Specification Sheets, 2021. https://onfi.org/files/onfi_5_0_gold.pdf. [47] Samsung. Samsung SSD PM1743 White Paper, 2024. https://download.semiconductor.samsung.com/resources/white- paper/PM1743_White_Paper_240510.pdf. [48] Aayush Gupta, Youngjae Kim, and Bhuvan Urgaonkar. DFTL: A Flash Translation Layer Employing Demand-Based Selective Caching of Page-Level Address Mappings. InProceedings of the 14th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2009. [49] Song Jiang, Lei Zhang, XinHao Yuan, Hao Hu, and Yu Chen. S-ftl: An efficient address translation for flash memory by exploiting spatial locality. InProceedings of the IEEE 27th Symposium on Mass Storage Systems and Technologies (MSST), 2011. [50] Jinghan Sun, Shaobo Li, Yunxin Sun, Chao Sun, Dejan Vucinic, and Jian Huang. Leaftl: A Learning-Based Flash Translation Layer for Solid-State Drives. InProceedings of the 28th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2023. [51] Junghee Lee, Youngjae Kim, Galen M. Shipman, Sarp Oral, and Jongman Kim. Preemptible I/O Scheduling of Garbage Collection for Solid State Drives.IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems (TCAD), 2013. [52] Pan Yang, Ni Xue, Yuqi Zhang, Yangxu Zhou, Li Sun, Wenwen Chen, Zhonggang Chen, Wei Xia, Junke Li, and Kihyoun Kwon. Reducing Garbage Collection Overhead in SSD Based on Workload Prediction. InProceedings of the 11th USENIX Workshop on Hot Topics in Storage and File Systems (HotStorage), 2019. [53] Wonkyung Kang, Dongkun Shin, and Sungjoo Yoo. Reinforcement Learning-Assisted Garbage Collection to Mitigate Long-Tail Latency in SSD.ACM Transactions on Embedded Computing Systems (TECS), 2017. [54] Jiayang Guo, Yiming Hu, Bo Mao, and Suzhen Wu. Parallelism and Garbage Collection Aware I/O Scheduler with Improved SSD Performance. InProceedings of the 2017 IEEE International Parallel and Distributed Processing Symposium (IPDPS), 2017. [55] Wonil Choi, Myoungsoo Jung, Mahmut Kandemir, and Chita Das. Parallelizing Garbage Collection with I/O to Improve Flash Resource Utilization. InProceedings of the 27th International Symposium on High-Performance Parallel and Distributed Computing (HPDC), 2018. [56] Narges Shahidi, Mahmut T. Kandemir, Mohammad Arjomand, Chita R. Das, Myoungsoo Jung, and Anand Siva- subramaniam. Exploring the Potentials of Parallel Garbage Collection in SSDs for Enterprise Storage Systems. In Proceedings of the 2016 International Conference for High Performance Computing, Networking, Storage and Analysis (SC), 2016. [57] Wonkyung Kang and Sungjoo Yoo. Dynamic Management of Key States for Reinforcement Learning-Assisted Garbage Collection to Reduce Long Tail Latency in SSD. InProceedings of the 55th Annual Design Automation Conference (DAC), 2018. [58] Jinhua Cui, Youtao Zhang, Jianhang Huang, Weiguo Wu, and Jun Yang. ShadowGC: Cooperative Garbage Collection with Multi-level Buffer for Performance Improvement in NAND Flash-Based SSDs. InProceedings of the 2018 Design, Automation & Test in Europe Conference & Exhibition (DATE), 2018. [59] Junghee Lee, Youngjae Kim, Galen M. Shipman, Sarp Oral, Feiyi Wang, and Jongman Kim. A Semi-Preemptive Garbage Collector for Solid State Drives. InProceedings of the IEEE International Symposium on Performance Analysis of Systems and Software (ISPASS), 2011. [60] Dharamjeet, Yi-Shen Chen, Tseng-Yi Chen, Yuan-Hung Kuan, and Yuan-Hao Chang. LLSM: A Lifetime-Aware Wear-Leveling for LSM-Tree on NAND Flash Memory.IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems (TCAD), 2022. [61] Jun Li, Xiaofei Xu, Xiaoning Peng, and Jianwei Liao. Pattern-Based Write Scheduling and Read Balance-Oriented Wear-Leveling for Solid State Drivers. InProceedings of the 2019 35th Symposium on Mass Storage Systems and Technologies (MSST), 2019. [62] Muthukumar Murugan and David.H.C. Du. Rejuvenator: A Static Wear Leveling Algorithm for NAND Flash Memory with Minimized Overhead. InProceedings of the 2011 27th Symposium on Mass Storage Systems and Technologies (MSST), 2011. [63] Arash Tavakkol, Mohammad Sadrosadati, Saugata Ghose, Jeremie Kim, Yixin Luo, Yaohua Wang, Nika Mansouri Ghiasi, Lois Orosa, Juan Gómez-Luna, and Onur Mutlu. FLIN: Enabling Fairness and Enhancing Performance in Modern NVMe Solid State Drives. InProceedings of the 45th Annual International Symposium on Computer Architecture (ISCA), 2018.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:29 [64] Byunghei Jun and Dongkun Shin. Workload-aware budget compensation scheduling for nvme solid state drives. In Proceedings of the 2015 4th IEEE Non-Volatile Memory System and Applications Symposium (NVMSA), 2015. [65] Myoungsoo Jung and Mahmut T. Kandemir. Sprinkler: Maximizing Resource Utilization in Many-Chip Solid State Disks. InProceedings of the 2014 IEEE International Symposium on High-Performance Computer Architecture (HPCA), 2014. [66] Nima Elyasi, Mohammad Arjomand, Anand Sivasubramaniam, Mahmut T Kandemir, Chita R Das, and Myoungsoo Jung. Exploiting intra-request slack to improve ssd performance. InProceedings of the 22nd ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2017. [67] Guanying Wu and Xubin He. Reducing SSD Read Latency via NAND Flash Program and Erase Suspension. In Proceedings of the 10th USENIX Conference on File and Storage Technologies (FAST), 2012. [68] Rino Micheloni, Alessia Marelli, and Kam Eshghi.Inside Solid State Drives (SSDs). 2018. [69] Jin Xue, Renhai Chen, and Zili Shao. Softssd: Software-defined ssd development platform for rapid flash firmware prototyping. InProceedings of the 40th IEEE International Conference on Computer Design (ICCD), 2022. [70] Arash Tavakkol, Juan G’omez-Luna, Mohammad Sadrosadati, Saugata Ghose, and Onur Mutlu. MQSim: A framework for enabling realistic studies of modern multi-queue SSD devices. InProceedings of the 16th USENIX Conference on File and Storage Technologies (FAST), 2018. [71] Samsung. Samsung V-NAND SSD 990 Pro Data Sheet, 2023. https://download.semiconductor.samsung.com/resourc es/data-sheet/samsung_nvme_ssd_990_pro_datasheet_rev.2.0.pdf. [72] Mingwei Zhang, Zheng Zhang, and Ravi Sahita. Checkpointing for DRAM-Less SSD, 2020. US Patent 10,754,785. [73] Yiying Zhang, Leo Prasath Arulraj, Andrea C Arpaci-Dusseau, and Remzi H Arpaci-Dusseau. De-Indirection for Flash-Based SSDs with Nameless Writes. InProceedings of the 10th USENIX Conference on File and Storage Technologies (FAST), 2012. [74] Joo-Young Hwang, Seokhwan Kim, Daejun Park, Yong-Gil Song, Junyoung Han, Seunghyun Choi, Sangyeun Cho, and Youjip Won. ZMS: Zone abstraction for mobile flash storage. InProceedings of the 2024 USENIX Annual Technical Conference (ATC), 2024. [75] Hyojun Kim and Seongjun Ahn. BPLRU: A Buffer Management Scheme for Improving Random Writes in Flash Storage. InProceedings of the 8th USENIX Conference on File and Storage Technologies (FAST), 2008. [76] Hyeon Gyu Lee, Juwon Lee, Minwook Kim, Donghwa Shin, Sungjin Lee, Bryan S Kim, Eunji Lee, and Sang Lyul Min. Spartanssd: A reliable ssd under capacitance constraints. InProceedings of the IEEE/ACM International Symposium on Low Power Electronics and Design (ISLPED), 2021. [77] Rino Micheloni, Luca Crippa, and Alessia Marelli.Inside NAND Flash Memories. 2010. [78] Jisung Park, Roknoddin Azizi, Geraldo F. Oliveira, Mohammad Sadrosadati, Rakesh Nadig, David Novo, Juan Gómez- Luna, Myungsuk Kim, and Onur Mutlu. Flash-Cosmos: In-Flash Bulk Bitwise Operations Using Inherent Computation Capability of NAND Flash Memory. InProceedings of the 2022 55th IEEE/ACM International Symposium on Microarchi- tecture (MICRO), 2022. [79] Kai Zhao, Wenzhe Zhao, Hongbin Sun, Xiaodong Zhang, Nanning Zheng, and Tong Zhang. LDPC-in-SSD: Making Advanced Error Correction Codes Work Effectively in Solid State Drives. In11th USENIX Conference on File and Storage Technologies (FAST), 2013. [80] Osso Vahabzadeh. LDPC codes: Principles and implementation aspects. InFlash Memory Summit (FMS), 2016. [81] David Declercq. Improving Waterfall Performance of Low Cost FAID LDPC Decoders. InFlash Memory Summit (FMS), 2019. [82] Robert Gallager. Low-Density Parity-Check Codes.IRE Transactions on Information Theory, 1962. [83] Micron. Product Flyer: Micron 3D NAND Flash Memory, 2016. https://www.micron.com/-/media/client/global/doc uments/products/product-flyer/3d_nand_flyer.pdf. [84] Zhenming Zhou, Murong Lang, and Li-Te Chang. Read disturb management, 2024. US Patent 12,051,471. [85] Hiroaki Tanaka. Memory System and Method of Controlling Memory System, 2016. US Patent App. 14/824,402. [86] Abdel Hakim Alhussien, Ludovic Danjean, Sundararajan Sankaranarayanan, and Erich Franz Haratsch. Read disturb detection based on dynamic bit error rate estimation, 2019. US Patent 10,482,983. [87] JEDEC. JESD218B.01: Solid-State Drive (SSD) Requirements and Endurance Test Method, 2016. [88] Cox, Alvin. JEDEC SSD Endurance Workloads, 2011. https://www.jedec.org/sites/default/files/Alvin_Cox%20%5BCo mpatibility%20Mode%5D_0.pdf. [89] Micron. Product Flyer: Micron 3D NAND Flash Memory, 2016. https://www.micron.com/-/media/client/global/doc uments/products/productflyer/3d_nand_flyer.pdf?la=en. [90] Micron. NAND Flash Die - Media 1Tb Die: x8 300mm QLC, 2022. https://static6.arrow.com/aropdfconversion/7fe70 6dfbdcc308f78d998e13cfe12b7146703a1/n48r-media-die-nand-datasheet.pdf. [91] ADATA. ADATA Premier SP550 SSD, 2019. https://www.adata.com/upload/downloadfile/Datasheet_SP550_EN_201 60401.pdf.
10:30 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park [92] ADATA. ADATA Ultimate SU800 SSD, 2024. https://www.adata.com/us/support/product/410/. [93] ADATA. ADATA Ultimate SU630 SSD, 2023. https://www.adata.com/us/support/product/591/. [94] Seagate. Seagate BarraCuda SSD, 2023. https://www.seagate.com/products/hard-drives/barracuda-qlc-ssd/. [95] Western Digital. WD Blue SSD, 2023. https://www.westerndigital.com/en-sg/products/internal-drives/wd-blue-sata- ssd. [96] Hynix. SK Hynix Gold S31 SSD, 2023. https://ssd.skhynix.com/gold_p31/. [97] Samsung. Samsung 860 EVO SSD, 2018. https://download.semiconductor.samsung.com/resources/data- sheet/Samsung_SSD_860_EVO_Data_Sheet_Rev1.pdf. [98] Samsung. Samsung 860 QVO SSD, 2018. https://download.semiconductor.samsung.com/resources/data- sheet/Samsung_SSD_860_QVO_Data_Sheet_Rev1.pdf. [99] Toshiba. Toshiba TR200 SSD, 2017. https://gzhls.at/blob/ldb/3/d/4/c/32616ebe4e85c4c3530c782df3ca466ae6e6.pdf. [100] Crucial. Crucial BX500 3D NAND TLC SSD, 2019. https://www.crucial.com/ssd/bx500/ct1000bx500ssd1. [101] Youngseop Shim, Myungsuk Kim, Myoungjun Chun, Jisung Park, Yoona Kim, and Jihong Kim. Exploiting Process Similarity of 3D Flash Memory for High Performance SSDs. InProceedings of the 2019 52nd IEEE/ACM International Symposium on Microarchitecture (MICRO), 2019. [102] Yixin Luo, Saugata Ghose, Yu Cai, Erich F. Haratsch, and Onur Mutlu. Improving 3D NAND Flash Memory Lifetime by Tolerating Early Retention Loss and Process Variation.Proceedings of the ACM on Measurement and Analysis of Computing Systems (POMACS), 2018. [103] Yi Wang, Lisha Dong, and Rui Mao. P-Alloc: Process-Variation Tolerant Reliability Management for 3D Charge- Trapping Flash Memory.ACM Transactions on Embedded Computing Systems (TECS), 2017. [104] Shuo-Han Chen, Yen-Ting Chen, Hsin-Wen Wei, and Wei-Kuan Shih. Boosting the Performance of 3D Charge Trap NAND Flash with Asymmetric Feature Process Size Characteristic. InProceedings of the 2017 54th ACM/EDAC/IEEE Design Automation Conference (DAC), 2017. [105] Chun-Hsiung Hung, Meng-Fan Chang, Yih-Shan Yang, Yao-Jen Kuo, Tzu-Neng Lai, Shin-Jang Shen, Jo-Yu Hsu, Shuo-Nan Hung, Hang-Ting Lue, Yen-Hao Shih, Shih-Lin Huang, Ti-Wen Chen, Tzung Shen Chen, Chung Kuang Chen, Chi-Yu Hung, and Chih-Yuan Lu. Layer-Aware Program-and-Read Schemes for 3D Stackable Vertical-Gate BE-SONOS NAND Flash Against Cross-Layer Process Variations.IEEE Journal of Solid-State Circuits (JSSC), 2015. [106] Jui-Nan Yen, Yao-Ching Hsieh, Cheng-Yu Chen, Tseng-Yi Chen, Chia-Lin Yang, Hsiang-Yun Cheng, and Yixin Luo. Efficient Bad Block Management with Cluster Similarity. InProceedings of the 2022 IEEE International Symposium on High-Performance Computer Architecture (HPCA), 2022. [107] Qiao Li, Min Ye, Yufei Cui, Liang Shi, Xiaoqiang Li, Tei-Wei Kuo, and Chun Jason Xue. Shaving Retries with Sentinels for Fast Read over High-Density 3D Flash. InProceedings of the 2020 53rd Annual IEEE/ACM International Symposium on Microarchitecture (MICRO), 2020. [108] Yu Cai, Erich F. Haratsch, Onur Mutlu, and Ken Mai. Threshold Voltage Distribution in MLC NAND Flash Memory: Characterization, Analysis, and Modeling. InProceedings of the 2013 Design, Automation & Test in Europe Conference & Exhibition (DATE), 2013. [109] Sungjun Cho, Beomjun Kim, Hyunuk Cho, Gyeongseob Seo, Onur Mutlu, Myungsuk Kim, and Jisung Park. AERO: Adaptive Erase Operation for Improving Lifetime and Performance of Modern NAND Flash-Based SSDs. InProceedings of the 29th ACM International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS), 2024. [110] Intel. Intel Core i9 Processor 14900K, 2023. https://www.intel.com/content/www/us/en/products/sku/236773/intel- core-i9-processor-14900k-36m-cache-up-to-6-00-ghz/specifications.html. [111] Jens Axboe. Flexible I/O Tester, 2025. https://github.com/axboe/fio. [112] NVM Express Workgroup. NVM Express® Base Specification, 2025. https://nvmexpress.org/wp-content/uploads/NV M-Express-Base-Specification-Revision-2.2-2025.03.11-Ratified.pdf. [113] Bruce Allen. Smartmontools, 2025. https://www.smartmontools.org/. [114] Micron Technology, Inc. Storage Executive Software, 2025. https://www.micron.com/sales-support/downloads/soft ware-drivers/storage-executive-software. [115] Sangjin Yoo and Dongkun Shin. Reinforcement Learning-Based SLC Cache Technique for Enhancing SSD Write Performance. InProceedings of the 12th USENIX Workshop on Hot Topics in Storage and File Systems (HotStorage), 2020. [116] Kulachet Tanpairoj, Sebastien Andre Jean, Kishore Kumar Muchherla, Ashutosh Malshe, and Jianmin Huang. SLC Cache Management, 2022. US Patent 11,237,737. [117] Phison. Pinnacle of Gen4 Power and Value, 2023. https://www.phison.com/images/products_datasheet/ProductBroc hure_Consumer_PS5027-E27T.pdf. [118] Weihua Liu, Fei Wu, Xiang Chen, Meng Zhang, Yu Wang, Xiangfeng Lu, and Changsheng Xie. Characterization Summary of Performance, Reliability, and Threshold Voltage Distribution of 3D Charge-Trap NAND Flash Memory. ACM Transactions on Storage (TOS), 2022.
Experimental Study on System-Level Performance Impact of Read Disturbance in Modern SSDs 10:31 [119] Keivan Alizadeh, Iman Mirzadeh, Dmitry Belenko, Karen Khatamifard, Minsik Cho, Carlo C Del Mundo, Mohammad Rastegari, and Mehrdad Farajtabar. LLM in a Flash: Efficient Large Language Model Inference with Limited Memory. InarXiv, 2023. [120] Yuyue Wang, Xiurui Pan, Yuda An, Jie Zhang, and Glenn Reinman. BeaconGNN: Large-Scale GNN Acceleration with Out-of-Order Streaming In-Storage Computing. InProceedings of the 2024 IEEE International Symposium on High-Performance Computer Architecture (HPCA), 2024. [121] Nika Mansouri Ghiasi, Mohammad Sadrosadati, Harun Mustafa, Arvid Gollwitzer, Can Firtina, Eudine Julien, Haiyu Mao, Joël Lindegger, Meryem Banu Cavlak, Mohammed Alser, Jisung Park, and Onur Mutlu. MegIS: High-Performance, Energy-Efficient, and Low-Cost Metagenomic Analysis with In-Storage Processing. InProceedings of the 51st Annual International Symposium on Computer Architecture (ISCA). [122] Guiqiang Dong, Ningde Xie, and Tong Zhang. Enabling NAND Flash Memory Use Soft-Decision Error Correction Codes at Minimal Read Latency Overhead.IEEE Transactions on Circuits and Systems I: Regular Papers, 2013. [123] Yishan Zhang, Chun Zhang, Zhiyuan Yan, Shuang Chen, and Hanjun Jiang. A High-Throughput Multi-Rate LDPC Decoder for Error Correction of Solid-State Drives. InIEEE Workshop on Signal Processing Systems (SiPS), 2015. [124] ONFI Workgroup. ONFI 3.0 Specification Sheets, 2011. https://onfi.org/files/onfi_3_0_gold.pdf. [125] Yixin Luo, Saugata Ghose, Yu Cai, Erich F. Haratsch, and Onur Mutlu. Enabling Accurate and Practical Online Flash Channel Modeling for Modern MLC NAND Flash Memory.IEEE Journal on Selected Areas in Communications (JSAC), 2016. [126] Yixin Luo, Saugata Ghose, Yu Cai, Erich F. Haratsch, and Onur Mutlu. HeatWatch: Improving 3D NAND Flash Memory Device Reliability by Exploiting Self-Recovery and Temperature Awareness. InProceedings of the 2018 IEEE International Symposium on High Performance Computer Architecture (HPCA), 2018. [127] Yixin Luo, Saugata Ghose, Yu Cai, Erich F. Haratsch, and Onur Mutlu. Improving 3D NAND Flash Memory Lifetime by Tolerating Early Retention Loss and Process Variation. InProceedings of the 2018 ACM on Measurement and Analysis of Computing Systems (SIGMETRICS), 2018. [128] Shiqiang Nie, Youtao Zhang, Weiguo Wu, and Jun Yang. Layer RBER Variation Aware Read Performance Optimization for 3D Flash Memories. InProceedings of the 53rd ACM/EDAC/IEEE Design Automation Conference (DAC), 2020. [129] Feng Chen, Rubao Lee, and Xiaodong Zhang. Essential Roles of Exploiting Internal Parallelism of Flash Memory Based Solid State Drives in High-Speed Data Processing. InProceedings of the 2011 IEEE International Symposium on High-Performance Computer Architecture (HPCA), 2011. [130] Hyukjoong Kim, Dongkun Shin, Yunho Jeong, and Kyunghom Kim. SHRD: Improving Spatial Locality in Flash Storage Accesses by Sequentializing in Host and Randomizing in Device. InProceedings of the 15th USENIX Conference on File and Storage Technologies (FAST), 2017. [131] Charles J. Camp and H. Frost Holloway. Reduction of read disturb errors in nand flash memory, 2010. US Patent 8,189,379. [132] Richard A. Mataya, Rancho Santo, Po-len Hsueh, and Mark Moshayedi. Flash Storage Device with Read Disturb Mitigation, 2014. US Patent 8,719,652. [133] Junghee Lee, Youngjae Kim, Galen M. Shipman, Sarp Oral, and Jongman Kim. Page Type-Aware Data Migration Technique for Read Disturb Management of NAND Flash Memory.IEEE Transactions on Very Large Scale Integration (VLSI) Systems, 2023. [134] Jaeyong Jeong, Sangwook Shane Hahn, Sungjin Lee, and Jihong Kim. Lifetime Improvement of NAND Flash-Based Storage Systems Using Dynamic Program and Erase Scaling. InProceedings of the 12th USENIX Conference on File and Storage Technologies (FAST), 2014. [135] Myungsuk Kim, Youngsun Song, Myoungsoo Jung, and Jihong Kim. SARO: A State-Aware Reliability Optimization Technique for High Density NAND Flash Memory. InProceedings of the Great Lakes Symposium on VLSI (GLSVLSI), 2018. [136] Yazhi Feng, Dan Feng, Wei Tong, Yu Jiang, and Chuanqi Liu. Using Disturbance Compensation and Data Clustering (DC)2 to Improve Reliability and Performance of 3D MLC Flash Memory. In35th International Conference on Computer Design (ICCD), 2017. [137] Haobo Wang, Nathan Wong, Tsung-Yi Chen, and Richard D. Wesel. Using Dynamic Allocation of Write Voltage to Extend Flash Memory Lifetime.IEEE Transactions on Communications, 2016. [138] Dong Guiqiang, Li Shu, and Zhang Tong. Using Data Postcompensation and Predistortion to Tolerate Cell-to-Cell Interference in MLC NAND Flash Memory.IEEE Transactions on Circuits and Systems I, 2010. [139] Da-Wei Chang, Wei-Cheng Lin, and Hsin-Hung Chen. FastRead: Improving Read Performance for Multi-Level-Cell Flash Memory.IEEE Transactions on Very Large Scale Integration (VLSI) Systems, 2016. [140] Jun Li, Bowen Huang, Zhibing Sha, Zhigang Cai, Jianwei Liao, Balazs Gerofi, and Yutaka Ishikawa. Mitigating Negative Impacts of Read Disturb in SSDs.ACM Transactions on Design Automation of Electronic Systems (TODAES), 2020.
10:32 Yonggon Park, Hyunuk Cho, Onur Mutlu, Sungjin Lee, and Jisung Park [141] Jianwei Liao, Jun Li, Mingwang Zhao, Zhibing Sha, and Zhigang Cai. Read Refresh Scheduling and Data Reallocation against Read Disturb in SSDs.ACM Transactions on Embedded Computing Systems (TECS), 2022. [142] Kanchan Joshi, Praval Choudhary, and Kaushal Yadav. Enabling NVMe WRR Support in Linux Block Layer. In Proceedings of the 9th USENIX Workshop on Hot Topics in Storage and File Systems (HotStorage), 2017. [143] Mohammad Hedayati, Kai Shen, Michael L. Scott, and Mike Marty. Multi-Queue Fair Queuing. InProceedings of the 2019 USENIX Annual Technical Conference (ATC), 2019. [144] Suli Yang, Tyler Harter, Nishant Agrawal, Salini Selvaraj Kowsalya, Anand Krishnamurthy, Samer Al-Kiswany, Rini T. Kaushik, Andrea C. Arpaci-Dusseau, and Remzi H. Arpaci-Dusseau. Split-Level I/O Scheduling. InProceedings of the 25th Symposium on Operating Systems Principles (SOSP), 2015. [145] David Shue, Michael J. Freedman, and Anees Shaikh. Performance Isolation and Fairness for Multi-Tenant Cloud Storage. InProceedings of the 10th USENIX Conference on Operating Systems Design and Implementation (OSDI), 2012. [146] Jiwon Woo, Minwoo Ahn, Gyusun Lee, and Jinkyu Jeong. Device-Direct Fair Queueing for NVMe SSDs. InProceedings of the 19th USENIX Conference on File and Storage Technologies (FAST), 2021. [147] Miryeong Kwon, Donghyun Gouk, Changrim Lee, Byounggeun Kim, Jooyoung Hwang, and Myoungsoo Jung. DC- Store: Eliminating Noisy Neighbor Containers Using Deterministic I/O Performance and Resource Isolation. In Proceedings of the 18th USENIX Conference on File and Storage Technologies (FAST), 2020. [148] Jian Huang, Anirudh Badam, Laura Caulfield, Suman Nath, Sudipta Sengupta, Bikash Sharma, and Moinuddin K. Qureshi. FlashBlox: Achieving Both Performance Isolation and Uniform Lifetime for Virtualized SSDs. InProceedings of the 15th USENIX Conference on File and Storage Technologies (FAST), 2017. [149] Shiqin Yan, Huaicheng Li, Mingzhe Hao, Michael Hao Tong, Swaminathan Sundararaman, Andrew A. Chien, and Haryadi S. Gunawi. Tiny-Tail Flash: Near-Perfect Elimination of Garbage Collection Tail Latencies in NAND SSDs. InProceedings of the 15th USENIX Conference on File and Storage Technologies (FAST), 2017. [150] Jaeho Kim, Donghee Lee, and Sam H. Noh. Towards SLO Complying SSDs Through OPS Isolation. InProceedings of the 13th USENIX Conference on File and Storage Technologies (FAST), 2015. [151] Micron. Micron 9400 SSD Series Technical Product Specification, 2025. https://assets.micron.com/adobe/assets/urn: aaid:aem:83accf2c-00af-4223-ab00-c40fb224ce6c/renditions/original/as/9400-nvme-ssd-tech-prod-spec.pdf. [152] Vasily Tarasov, Erez Zadok, and Spencer Shepler. Filebench: A flexible framework for file system benchmarking. USENIX ;login:, 2016. [153] Ying Sheng, Lianmin Zheng, Binhang Yuan, Zhuohan Li, Max Ryabinin, Beidi Chen, Percy Liang, Christopher Ré, Ion Stoica, and Ce Zhang. FlexGen: High-Throughput Generative Inference of Large Language Models with a Single GPU. InProceedings of the 40th International Conference on Machine Learning (ICML), 2023. [154] Reza Yazdani Aminabadi, Samyam Rajbhandari, Minjia Zhang, Ammar Ahmad Awan, Du Li, Cheng Li, Elton Zheng, Jeff Rasley, Shaden Smith, Olatunji Ruwase, and Yuxiong He. DeepSpeed Inference: Enabling Efficient Inference of Transformer Models at Unprecedented Scale. InarXiv presents, 2022. [155] NVM Express Workgroup. NVM Express® Base Specification, 2021. https://nvmexpress.org/wp-content/uploads/NV Me-NVM-Express-2.0a-2021.07.26-Ratified.pdf. [156] Myoungjun Chun, Myungsuk Kim, Dusol Lee, Jisung Park, and Jihong Kim. ReadGuard: Integrated SSD Management for Priority-Aware Read Performance Differentiation.ACM Transactions on Storage (TOS), 2024. [157] Shaoqi Yang, Xiaohuan Zhao, Peng Guo, Qianwen Wang, Guangkuo Yang, Xinyi Guo, Pengpeng Sang, Jixuan Wu, Xuepeng Zhan, and Jiezhi Chen. Comprehensive Characterizations on Read Disturbs in QLC Charge-Trap (CT) 3D NAND Flash. InProceedings of the IEEE 17th International Conference on Solid-State & Integrated Circuit Technology (ICSICT), 2024. [158] Jaeyong Lee, Beomjun Kim, Myoungjun Chun, Myungsuk Kim, and Jihong Kim. DEAR: Improving Performance and Lifetime of SSDs Using Dynamic Error-Aware Refresh. InProceedings of the 2025 58th IEEE/ACM International Symposium on Microarchitecture (MICRO), 2025. [159] Qiao Li, Yu Chen, Guanyu Wu, Yajuan Du, Min Ye, Xinbiao Gan, Jie Zhang, Zhirong Shen, Jiwu Shu, and Chun Xue. Characterizing and Optimizing LDPC Performance on 3D NAND Flash Memories.ACM Transactions on Architecture and Code Optimization (TACO), 2024. [160] Lanlan Cui, Xiaojian Liu, Fei Wu, and Changsheng Xie. Improving LDPC Decoding Performance for 3D TLC NAND Flash by LLR Optimization Scheme for Hard and Soft Decision.ACM Transactions on Design Automation of Electronic Systems, 2022. [161] Li Wei Liu, Yen Chin Liao, and Hsie-Chia Chang. UP-GDBF: A 19.3 Gbps Error Floor Free 4KB LDPC Decoder for NAND Flash Applications.IEEE Open Journal of Circuits and Systems (OJCAS), 2022.
第二部分:解析(深度解读)
核心论点
随存储密度数十年提升,NAND 闪存在现代计算中举足轻重,但可靠性随之下降。读干扰(read disturbance)因影响加剧而成为主要可靠性隐患。以往研究多关注比特错误率,本文首次系统量化读干扰对「系统级 I/O 性能」的影响——例如读刷新(read reclaim)引发的尾延迟(tail latency)与吞吐下降,而非仅数据完整性。
关键概念
- 读干扰 / 读刷新(read reclaim):频繁读某一页会干扰同块其他页,需触发刷新,带来性能开销。
- 尾延迟:少数请求的极端延迟,对服务等级(SLO)影响大。
- 可靠性–性能权衡:密度↑ ⇒ 可靠性↓,读干扰成为系统性能的关键约束。
技术趋势与判断
- 存储密度提升使读干扰从「数据完整性」问题升级为「系统性能」问题,对云存储与 AI 训练数据管线有意义。
- 与 AI 基础设施主线相关:数据搬运与存储带宽/延迟直接影响训练与推理效率。
与本站其他文章的连接
- 计算机体系结构/存储子系统,与 AI 硬件(HBM/互连/数据通路)主线互补。
风险提示